Archgard 36- D VI E40LN - 1 Скачать руководство пользователя страница 2

2

TABLE OF CONTENTS

1. 0  In t r o d u c t i o n

3

2. 0  Sa f e t y  In f o r m a t i o n

4

3. 0  Te c h n i c a l  In f o r m a t i o n

5

3.1  Appliance Certification

5

3.2  Installation Codes

5

3.3  Specifications

5

3.4  High Altitude Installation

5

4. 0  Ra t i n g  Pl a t e

6

5. 0  In s t a l l a t i o n  C h e c k l i s t

7

6. 0  Ap p l i a n c e  Ov e r v i e w

8

6.1  Appliance Overview

8

6.2  Leveling the Appliance

8

6.3  Configuring the Controls

8

6.4  Accessing the Control Board

9

6.5  Accessing the Gas Valve

9

7 . 0  El e c t r i c a l  C o n n e c t i o n s

9

8 . 0  Ap p l i a n c e  Di m e n s i o n s

10

8.1 Controls in Dimensions

10

8.2 Controls out Dimensions

11

9 . 0  Mi n i m u m  Op e n i n g  Di m e n s i o n s

12

9.1  Factory Built Fireplaces

13

9.2  Refacing a Masonry Fireplace

14

10. 0  C l e a r a n c e s  t o  C o m b u s t i b l e s

15

10.1  Mantel Clearances

15

10.2  Minimum Sidewall Clearances

15

10.3  Hearth Clearances

16

11. 0  Ga s  C o n n e c t i o n s

17

11.1  Clocking Procedure

17

12. 0  C o n v e r s i o n  K i t  In s t r u c t i o n s

18

12.1  Prepare the Fireplace

18

12.2  Pilot Conversion

18

12.3  Convert the Gas Valve

19

12.4  Complete the Conversion

19

13. 0  Ve n t i n g  In s t r u c t i o n s

20

13.1  Exhaust Restrictor

21

13.2  Approved Terminations

21

13.3  Min/Max Vent Run

23

13.4  Using a Co-linear to Coaxial Adapter

24

14. 0  Ba r r i e r  Sc r e e n  In s t a l l a t i o n

25

15. 0  Gl a s s  Do o r  In s t a l l a t i o n

26

15.1  If Your Glass Breaks

27

16. 0  Su r r o u n d  In s t a l l a t i o n

28

16.1  Surround Dimensions

29

16.2  Trimmable Surround Dimensions

30

16.3  Dimensions of Fronts

31

16.4  Dimensions of Decorative Trims

32

16.5  Dimensions of Decorative Plinths

33

16.6  Bottom Filler Plate

34

17 . 0  Fi r e b o x  Li n e r  In s t a l l a t i o n

35

17.1  Brick Panel Installation

35

17.2  Reflective Glass Installation

37

18 . 0  Me d i a  In s t a l l a t i o n

39

18.1  Log Set

39

19 . 0  Op e r a t i o n

44

19.1  Before Lighting

44

19.2  First Fire

44

19.3  Lighting Instructions

45

19.4  Dynamic Start Advantage

46

19.5  Remote Control Operation

47

20. 0  Ma i n t e n a n c e

53

20.1  Cleaning and Routine Maintenance

53

20.2  Servicing Under Warranty

54

20.3  Checking Inlet and Outlet Pressure

54

20.4  Checking and Adjusting Pilot

54

20.5  Adjusting the Primary Air

55

20.6  Replacing Batteries

55

20.7  Replacing Fuse

56

20.8  Replacing Light Bulbs

56

20.9  Replacing the Control Board

57

20.10  Removing the Intake Restrictor

58

20.11  Removing the Burner

59

20.12  Removing the Pilot

60

20.13  Replacing the Fan

63

20.14  Replacing Light Bases

65

20.15  Wiring Schematic

67

20.16  Troubleshooting

68

21. 0  Fr e q u e n t l y  As k e d  Q u e s t i o n s

69

22. 0  Re p l a c e m e n t  Pa r t s  Li s t

70

Содержание 36- D VI E40LN - 1

Страница 1: ...e r a t i n g p l a t e Th i s a p p l i a n c e i s n o t c o n v e r t i b l e f o r u s e with other gases unless a certified kit is used W ARNING If t h e i n f o r m a t i o n i n t h e s e i n s...

Страница 2: ...ations 21 13 3 Min Max Vent Run 23 13 4 Using a Co linear to Coaxial Adapter 24 14 0 Ba r r i e r Sc r e e n In s t a l l a t i o n 25 15 0 Gl a s s Do o r In s t a l l a t i o n 26 15 1 If Your Glass...

Страница 3: ...and personal tastes Electronic Control System This fireplace comes standard with the Dynamic Start Advantage This new electronic ignition system is the latest in fireplace technology It helps to creat...

Страница 4: ...tall an adjustable safety gate to keep toddlers young children and other at risk individuals out of the room and away from hot surfaces Do not store or place combustibles gasoline and other flammable...

Страница 5: ...ith local code or current National Electrical code ANSI NFPA No 70 1987 in the US and in Canada the current Canadian Electrical Code CSA C22 1 This appliance is certified for installation in a bedroom...

Страница 6: ...f none follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 or Natural Gas and Propane Installation Codes CSA B149 1 Electrical connections and grounding must be in accordance with local codes if any...

Страница 7: ...fuel fireplace damper Terminations installed and sealed in compliance with local building code Direct vent termination is highest point in vent assembly Wiring Electrical Section 7 0 Y ES NO IF NO W H...

Страница 8: ...Ap p l i a n c e The 36 DVIE40LN 1 is equipped with front and rear leveling bolts The fireplace has the ability to independently level left right and front back Leveling is done from the bottom of th...

Страница 9: ...l module Do not cut or remove the grounding prong from the main power supply plug C AU TION Label all wires prior to disconnection when servicing NOTE This appliance when installed must be electricall...

Страница 10: ...m In c h e s m m In c h e s m m In c h e s m m In c h e s m m FRONT 33 39 848 11 21 89 556 01 37 37 949 2 30 56 776 22 36 42 925 07 19 00 482 6 TOP 21 84 554 74 18 51 470 15 19 51 495 55 1 00 25 4 47...

Страница 11: ...t r i c Eq u i v a l e n t s In c h e s m m In c h e s m m In c h e s m m In c h e s m m In c h e s m m In c h e s m m FRONT 33 39 848 11 21 89 556 01 46 88 1190 75 30 56 775 22 36 42 925 07 19 00 482...

Страница 12: ...n outs must fit properly W ARNING This fireplace has been converted for use with a gas fireplace insert only and cannot be used for burning wood or solid fuels unless all original parts have been repl...

Страница 13: ...ibited except the metal floor J as specified The insulation H and any structured rigid frame member must not be removed or altered side and top of door frame side and top of the face of fireplace meta...

Страница 14: ...material Using Steel Studs and Cement Board on Wood Fireplaces Brick rock facing may be removed and replaced with non combustible materials like steel studs and cement board Only the facing material...

Страница 15: ...aterial and used as a factory built gas fireplace zero clearance fireplace Fi g u r e 10 1 01 10 1 Ma n t e l C l e a r a n c e s 10 2 Mi n i m u m Si d e w a l l C l e a r a n c e s Fi g u r e 10 2 0...

Страница 16: ...tible material closer than 9 228 6 mm to the bottom of the gas fireplace insert regardless of whether a noncombustible material covers the combustible material This includes any type of framing undern...

Страница 17: ...cturer s warranty Na t u r a l Ga s Pr e s s u r e Se t t i n g s The inlet supply or line pressure must be a minimum of 5 0 W C 1 2 kPa and a maximum of 14 0 W C 3 5 kPa The orifice is a 3 4 mm drill...

Страница 18: ...36 C K ELP for LP gas and 36 C K ENG for Natural Gas KIT INCLUDES Gas conversion label 303 0128 Burner orifice part number 301 0068 48 48 DMS 1 93 mm for LPG part number 301 0068 3 4 3 4 mm for NG Ins...

Страница 19: ...le 3 Ensure the rubber gasket D which is prefitted as part of assembly E is properly positioned see Fi g u r e 12 3 02 otherwise fit the gasket as shown Fi g u r e 12 3 02 4 Install the new STEPPER MO...

Страница 20: ...sert Masonry chimneys may take various contours which the flexible liner will accommodate however keep the flexible liner as straight as possible avoiding unnecessary bending but at all times keep a m...

Страница 21: ...e following page 13 1 Ex h a u s t Re s t r i c t o r This appliance includes two exhaust restrictors in the manual bag These restrictors may be required if the vent length exceeds 20 6 1 M Ve n t l e...

Страница 22: ...VWG TM SVTS N A High Wind Shield Rectangular N A N A N A TM CTS N A Co linear High Wind Vert Term Kit with 35 ft Flex for Masonry Chimney 94203370HWS 1604645 46DVA CL33 TM ALK33 DVIK33 Not High Wind C...

Страница 23: ...t as per terminal manufacturers instruction DO NOT U SE SILIC ONE 7 Seal and attach the end of the flex liner marked A i r In t a k e to the collar marked Ai r In t a k e on the appliance with the co...

Страница 24: ...e installation must conform with the local codes or in the absence of local codes with the current National Fuel Gas Code ANSI Z223 1 NFPA 54 in the US or Installation Code CAN CGA B149 1 in Canada El...

Страница 25: ...shell top is not shown to illustrate installation St e p 2 The hooks on the bottom of the barrier screen are designed to slide between the glass and the lower edge of the door frame St e p 3 Slide th...

Страница 26: ...install or when cleaning as high temperatures can bake these prints on permanently Inspect the door gasket to ensure no damage has occurred when installing the door St e p 1 Hold the glass door at an...

Страница 27: ...door assembly and barrier screen NOTE the NEW door will emit some odor when the appliance is lit The odor will dissipate after the gasket material within the door has cured Be sure there are no finger...

Страница 28: ...tains four tabs see Fi g u r e 16 0 01 which insert in slots in the fireplace see Fi g u r e 16 0 02 to hold the surround in place Align the tabs on both sides of the fireplace and hook the tabs in th...

Страница 29: ...52 125 132 4 cm C 30 31 76 99 cm 32 75 83 19 cm D 1 2 54 cm 2 5 6 35 cm 1 2 54 cm 2 5 6 35 cm E 2 42 6 15 cm Fo u r Si d e d Su r r o u n d s 36 SK 4SBS Sm a l l Sh a l l o w 36 SK 4SBD Sm a l l De e...

Страница 30: ...30 Installation 16 2 Tr i m m a b l e Su r r o u n d Di m e n s i o n s 99 06cm 39 000in 16 35cm 6 438in 119 38cm 47 000in 19 26cm 7 581in 6 15cm 2 420in Fi g u r e 16 2 01...

Страница 31: ...02 cm D 30 31 76 99 cm E 1 2 54 cm 2 5 6 35 cm F 0 90 2 29 cm G 2 42 6 15 cm Ha r r i s o n Mi l l s Fr o n t s 36 SDSHMBS 36 SDSHMBD A 5 5 13 97 cm B 4 91 12 47 cm C 47 25 120 02 cm D 30 31 76 99 cm...

Страница 32: ...e n s i o n s o f De c o r a t i v e Tr i m s 99 38cm 39 125in 6 70cm 2 638in 2 638in 6 70cm 66 61cm 26 226in Fi g u r e 16 4 01 99 38cm 39 125in 6 70cm 2 638in 2 638in 6 70cm 2 638in 6 70cm 73 41cm 2...

Страница 33: ...PSD2 2 5 08 cm 47 75 121 29 cm 2 67 6 78 cm 2 67 6 78 cm 36 DPSD4 4 10 16 cm 36 DPSD6 6 15 24 cm Fi g u r e 16 5 01 Fi g u r e 16 5 02 Sm a l l Pl i n t h s For use with 36 SKLBS or 36 SKLBD A B C D S...

Страница 34: ...r e 16 6 02 Fi g u r e 16 6 01 Fi g u r e 16 6 03 After installing the surround align the Bottom Filler Plate included with your fireplace with the underside of the surround Slide the plate under the...

Страница 35: ...r Before you begin Make sure the fireplace is o and cool prior to installation En s u r e t h e g a s s u p p l y i s t u r n e d OFF d i s c o n n e c t t h e p o w e r s u p p l y Remove barrier scr...

Страница 36: ...ing side panel Fi g u r e 17 1 06 Fi g u r e 17 1 07 St e p 8 Use the remaining brick panel retainer clip to secure the remaining side using the screw removed in St e p 1 Fi g u r e 17 1 08 Fi g u r e...

Страница 37: ...tion En s u r e t h e g a s s u p p l y i s t u r n e d OFF d i s c o n n e c t t h e p o w e r s u p p l y Remove barrier screen see Se c t i o n 14 0 Remove Glass Door see Se c t i o n 15 0 St e p 1...

Страница 38: ...er clip to secure the left panel in place Le f t C l i p St e p 10 Repeat St e p 8 through St e p 9 for the right panel Ri g h t C l i p Fi g u r e 17 2 10 Fi g u r e 17 2 11 St e p 11 Insert the uppe...

Страница 39: ...the package Please report any damage immediately to your Authorized Archgard Dealer Gas and vent connection must be made before installing the embers and logs on the pan burner C AU TION DO NOT block...

Страница 40: ...8 1 06 St e p 7 Continue to add embers between the logs in the back of the fireplace Do not block secondary air under the logs Do not block burner openings Fi g u r e 18 1 07 Fi g u r e 18 1 08 St e p...

Страница 41: ...the secondary air dam Be sure to leave some spacing between the embers along the air dam and along the edge of the logs to promote air flow Ai r Da m St e p 2 Place an even layer of embers along the...

Страница 42: ...ixture of both the firebox will be filled with a naturalistic glow St e p 1 Remove embers from the bag Be sure to follow handling instructions on the bag Fi g u r e 18 1 14 St e p 2 Separate embers by...

Страница 43: ...lack Embers 2 cup bag 2 310 6400 4 Log 4 Front Left 1 310 0019 Platinum Embers 1 bag 1 W ARNING Never use unapproved burner media such as rock wool or similar material The use of unapproved burner med...

Страница 44: ...been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water 4 This appliance...

Страница 45: ...45 Operation 19 3 Li g h t i n g In s t r u c t i o n s The following information may be found on the fireplace rating plate See Se c t i o n 6 1 for the rating plate location Fi g u r e 19 3 1...

Страница 46: ...eplace you build a fire You start with a little bit of tinder and kindling to create small fire and then work your way up to larger logs once a draft has been established Dynamic Start uses the same p...

Страница 47: ...ive LCD display A Mode Key is provided to index between the features and a Thermostat Key is used for on off or to index through the thermostat function Additionally a Key Lock function is provided AT...

Страница 48: ...a y W ARNING THE REMOTE AND RECEIVER ARE RADIO FREQUENCY DEVICES PLACING THE REMOTE IN OR NEAR METAL ENCLOSURES MAY REDUCE THE SIGNAL RANGE Hand held Remote optional Fi g u r e 19 5 02 Fi g u r e 19 5...

Страница 49: ...key on the remote The IFC module will beep four 4 times to indicate that it has successfully synced with the remote Turn the fireplace OFF using the ON OFF button on the remote to complete initializat...

Страница 50: ...iance is equipped with a hot air circulating fan the speed of the fan can be controlled by the Proflame system The fan speed can be adjusted through six 6 speeds To activate this function use the Mode...

Страница 51: ...e 19 5 10 Fi g u r e 19 5 11 Continuous Pilot on Demand Intermittent Pilot CPI IPI Selection With the system in OFF position press the Mode Key to index to the CPI mode icon Pressing the UP Arrow Key...

Страница 52: ...he MODE and UP Keys at the same time To deactivate this function press the MODE and UP Keys at the same time Low Battery Power Detection Less than 4V Re m o t e The life span of the remote control bat...

Страница 53: ...reak them Do not wash logs with any liquid While the logs are removed check that all burner openings are not obstructed and it is recommended you use a vacuum cleaner to clean off any dust or lint Vac...

Страница 54: ...pressure test taps are located on the valve s front face The inlet is marked IN and the outlet is marked OU T See Fi g u r e 20 3 01 3 Loosen the set screw inside the tap with a screwdriver 4 Connect...

Страница 55: ...N Do not adjust primary air below specified opening on the rating plate Fi g u r e 20 5 02 Fi g u r e 20 5 01 C l o c k w i s e Op e n a i r s h u t t e r C o u n t e r c l o c k w i s e C l o s e a i...

Страница 56: ...andle bulbs with cotton gloves as finger prints may reduce the life of the bulb We recommend replacing both bulbs at the same time 1 Ensure the fireplace is off and cool before servicing 2 Disconnect...

Страница 57: ...h the new control board and secure using nuts removed in the previous step 5 Reconnect all connections 6 Replace the fireplace surround 7 Supply power to the fireplace and verify proper operation C AU...

Страница 58: ...c t i o n 20 11 St e p 1 Remove the 2 Tek screws securing the rear firebox panel Fi g u r e 20 10 01 St e p 2 Remove the rear firebox panel Fi g u r e 20 10 02 St e p 3 Remove the 5 Tek screws securi...

Страница 59: ...t i o n 15 0 Remove burner media See Se c t i o n 18 0 Remove panel set if applicable See Se c t i o n 17 0 St e p 1 Remove the 5 Tek screws securing the ember strip at the front of the burner St e p...

Страница 60: ...shield Remove the pilot shield from the fireplace Fi g u r e 20 12 01 St e p 2 Remove the 2 screws securing the rear firebox panel Fi g u r e 20 12 02 St e p 3 Slide the bottom of the rear firebox pa...

Страница 61: ...lug the fan while removing from the fireplace Fi g u r e 20 12 06 St e p 7 Remove the 2 screws securing the pilot Fi g u r e 20 12 07 St e p 8 Remove the screw securing the pilot ground wire Fi g u r...

Страница 62: ...2 Installation is the reverse of removal Be sure to bundle wires using cable ties upon install Fi g u r e 20 12 12 IMPORTANT Ensure there are no gas leaks Test the operation of the pilot and burner fl...

Страница 63: ...when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing This appliance when installed must be electrically grounded in accordance with...

Страница 64: ...e removing from the fireplace Fi g u r e 20 13 06 St e p 7 Remove the 4 screws securing the old fan to the fan bracket Fi g u r e 20 13 07 IMPORTANT Ensure there are no gas leaks Test the operation of...

Страница 65: ...ed must be electrically grounded in accordance with local codes or in the absence of local codes with the Na t i o n a l El e c t r i c a l C o d e ANSI NFPA 7 0 o r t h e C a n a d i a n El e c t r i...

Страница 66: ...Unplug the light wire from the wiring harness Fi g u r e 20 14 03 Wiring harness behind firebox In s t a l l a t i o n i s t h e r e v e r s e o f r e m o v a l IMPORTANT Ensure there are no gas leak...

Страница 67: ...67 Maintenance 20 15 W i r i n g Sc h e m a t i c Blue IPI CPI Yellow APS On Off override jumper Ignition Pilot Flame sensor SW1 Botton red Sync button Fi g u r e 20 15 01...

Страница 68: ...fully engulf the sensor rod and must be stable 5 Check supply pressure 6 Ensure the ground wire from the pilot is connected to the fireplace ground location The pilot was lit but will randomly go out...

Страница 69: ...pletes its heating function You will likely hear these same sounds more on start up and shut down This is normal for steel fireplaces Q I hear a click when my main burner turns ON or OFF A Your Gas Co...

Страница 70: ...A 305 0060 Battery Back up EA RP 305 2080 Fuse 3 15A 250V Pack of 5 EA 301 0068 3 4 Orifice 3 4 mm for Natural Gas EA 301 0068 48 Orifice 48 DMS 1 93 mm for Propane EA 308 0124 Pilot Assembly EA 314 0...

Страница 71: ...e and original proof of purchase Any defective part in our judgment will be repaired or replaced at Archgard s discretion The dealer must obtain approval from Archgard before any repairs are made W AR...

Страница 72: ...NOTES...

Страница 73: ...NOTES...

Страница 74: ...NOTES...

Страница 75: ...CLOSED Model 36 DVIE40LN 1 Serial Date Installed Name Address City State Prov ZIP Phone _____ Dealer s Name Address City State Prov ZIP Phone _____ Installer s Name Address City State Prov ZIP Phone _...

Страница 76: ......

Отзывы: