Installation
10. 3 He a r t h C l e a r a n c e s
Fi g u r e 10. 3. 02
Fi g u r e 10. 3. 01
Non Combustible
Zone
16”
Non Combustible
Zone
16”
31 3/4”
33.39"
(848.1 mm)
16" (406.4 mm)
16" (406.4 mm)
Non Combustible
Zone
16”
Non Combustible
Zone
16”
31 3/4”
9"
(228.6 mm)
The Non Combustible
Zone may contain any
noncombustible material or
open air space. Never use
combustible materials within
the Non Combustible Zone.
Combustible Zone
Any hearth that extends outward in front of the insert must not have any combustible material closer than 9" (228.6 mm) to the bottom
of the gas fireplace insert regardless of whether a noncombustible material covers the combustible material. This includes any type of
framing underneath a noncombustible material such as tile, marble, or stone. Any material farther than 9" (228.6 mm) to the bottom or
16" (406.4 mm) from the front of the masonry opening of the existing fireplace can be combustible.
W ARNING
Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance
may result in property damage or personal injury.
NOTE
All specified clearances must be maintained from the top surface of carpeting, tile, etc.