6
General Information
4.0 Rating Plate
SAMPLE
Figure 4.0.01:
MODEL:
345-DVTE31LN-1
DO NOT REMOVE THIS LABEL
LISTED VENTED GAS FIREPLACE HEATER and GAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES. Tested to: ANSI
Z21.88-2017 / CSA 2.33-2017, CSA 2.17-2017, CSA P.4.1-15, and CSA 22.2 No.3-M1988 (R2014). This vented gas fireplace heater
is not for use with air filters. Certified for use in both CANADA and USA.
VENTED GAS FIREPLACE HEATER-NOT FOR USE WITH SOLID FUEL.
Manufactured as Natural Gas
NG
LPG
Input rating
17,000 - 31,000 BTU/hr
(4.98 - 9.09 kW)
16,000 - 30,000 BTU/hr
(4.69 - 8.79 kW)
Manifold Pressure
1.1 - 3.8 in. W.C. (0.27 - 0.95 kPa)
2.9 - 11.0 in. W.C. (0.72 - 2.74 kPa)
Orifice size
#36 DMS (2.71 mm dia.)
#52 DMS (1.61 mm dia.)
Supply pressure (Min - Max)
5 - 14 in. W.C. (1.2 - 3.5 kPa)
12 - 14 in. W.C. (2.99 - 3.5 kPa)
Burner Primary Air Setting
1/8” (3.175 mm) Open
1/2” (12.7 mm) Open
Altitude
0 - 4500 ft (0 - 1372 m)
0 - 4500 ft (0 - 1372 m)
Gas Control
SIT 885 Proflame II Dynamic Start with Continuous POD
Electrical rating
120 VAC, 60 Hz, less than 2 A.
P.4.1 Fireplace Efficiency (FE)
67.98%
Replacement fan
Part no. RF-305-0024 fan must be used
Keep burner and control compartment clean.
See Instructions accompanying the heater.
Optional fuel conversion kit : See Manual
Minimum clearances to Combustibles:
Chase sides, back & top from fireplace standoffs: 0” (0 cm).
Interior sidewall from fireplace opening: 4” (10.2 cm).
Mantle: 8” (20.32 cm) mantel at min 21.25” (53.975 cm) from top of the
fireplace opening.
Vent pipe: Sides & Bottom: 1” (2.54 cm), Top: 2” (5.08 mm).
Ceiling: 60” (152.4 cm) from fireplace opening.
See Manual for additional dimensions and clearances.
See IHEAT Manual for clearances with IHEAT installed.
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI
Z223.1/NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1. Electrical connections and grounding must
be in accordance with local codes, if any; if none, follow the current CAN/CSA C22.1 in Canada and ANSI/NFPA 70 in the
US. This appliance is certified for installation in a bedroom or a bed sitting room. This appliance is only for use with the gas
indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where
not prohibited by local codes. See owner’s manual for details. This appliance is not convertible with other gases, unless a
certified kit is used.
WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Refer
to the owner’s information manual provided with this appliance. For assistance or additional information consult a
qualified installer, service agency, or the gas supplier. This appliance must be properly connected to a Direct Vent
venting system in accordance with the manufacturer’s installation instructions.
WARNING: Failure to install this appliance per the manufacturer’s instructions or failure to use only parts specifically
approved with this appliance may result in property damage or personal injury.
WARNING: Do not operate the appliance until all sections have been assembled and installed in accordance with the
manufacturer’s instructions.
WARNING: Operation of this appliance when not connected to a properly installed and maintained venting system can result
in carbon monoxide (CO) poisoning and possible death.
Only doors certified with the appliance shall be used.
For use with Archgard barrier screen part #345-BS. Follow installation instructions.
Optional Archgard barrier screens available. See the Installation manual for options.
Made in Canada by:
Archgard Industries Ltd.
7116 Beatty Dr., Mission, B.C.
July 2020 303-3345-01
MANUFACTURE DATE:
2020 2021 2022 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC