24
Installation
10.3 Vent Restrictor Configuration
This fireplace is shipped without the restrictor plates installed. Follow the chart in
Section 10.2
for recommended settings based
on venting configuration. It is important to remember each installation is unique and affected by various factors including venting
configuration, altitude and climate. Therefore, after fireplace installation is complete, restrictor adjustments may be necessary. Use the
following steps to adjust the vent restrictor.
Before installation:
•
Disconnect gas and electrical supply to the fireplace (including backup batteries)
•
Remove the barrier screen (see
Section 6.3
)
•
Remove the glass door assembly (see
Section 6.4
)
Step 1:
Remove the three (3) 1/4" Tek Screws from the outer
baffle.
Step 2:
Remove the outer baffle.
Figure 10.3.01:
Figure 10.3.02:
Step 3:
Remove the three (4) 1/4" Tek Screws securing the inner
baffle. Remove the inner baffle.
Figure 10.3.03:
Step 4:
Remove the three (6) 1/4" Tek Screws securing the
restrictor plates.
Figure 10.3.04: