5
General Information
Technical Information
Appliance Certification
This appliance was listed by QAI Laboratories Inc to the following USA and Canadian gas appliance standards:
•
ANSI Z21.88-2014 / CSA 2.33-2014 Vented Gas Fireplace Heaters,
•
CAN/CGA 2.17-M91 (R2009) Gas Fired Appliances for use at High Altitudes,
•
CAN/CSA – P.4.1(2009) – Testing Method for Measuring Annual Fireplace Efficiency,
•
CSA C22.2 No.3 – M1988(R.2014) – Electrical Features of Fuel-Burning Equipment
The listing label is attached to the appliance on the bottom right side of the appliance.
A copy is shown on page 6.
Commonwealth of Massachusetts
: This appliance has been manufactured in accordance with Massachusetts code 248 CMR 5.00.
Approval Code: G1-0717-621. (http://license.reg.state.ma.us/public/licque.asp).
Please contact Archgard Industries Ltd., if you have any questions regarding the certification of this appliance.
Installation Codes
This appliance must be installed by a qualified gas appliance installer. The installation must conform with the local codes or, in
the absence of local codes, with the current National Fuel Gas Code ANSI Z223.1/ NFPA 54 in the US, or Installation Code CAN/
CGA-B149.1 in Canada. Electrical connections and grounding must conform with local code, or current National Electrical code ANSI/
NFPA No. 70-1987 in the US, and in Canada the current Canadian Electrical Code CSA C22.1.
We recommend that our gas hearth products be installed and serviced by professionals who are certified in the U.S. by the
National Fireplace Institute® (NFI) as NFI Gas Specialists.
Specifications
Natural Gas (NG)
Propane (LP)
Manifold Pressure
3.5 - 1.6 in. W.C. (0.9 - 0.4 kPa)
10.0 - 6.4 in. W.C. (2.5 - 1.6 kPa)
Min. Supply Pressure
Max Supply Pressure
5 in. W.C. (1.2 kPa)
14 in. W.C. (3.5 kPa)
11.0 in. W.C. (2.73 kPa)
14.0 in. W.C. (3.5 kPa)
Orifice Size
#33 DMS (2.87 mm dia)
#51 DMS (1.70 mm dia)
Nominal Input Rating
22,000 - 33,000 BTU/hr (6.1- 9.6kW)
24,000 - 31,000 BTU/hr (6.9 -9.0kW)
P.4 Fireplace Efficiency
(FE)
70.26%
P.4 Steady State Efficiency
73.22%
Electrical Requirements
120 VAC, 60Hz less than 2 A.
120 VAC, 60Hz less than 2 A.
Gas Control
SIT 820 Nova
SIT 820 Nova
Altitude
0 - 4,500 ft. (0 - 1372 M)
0 - 4,500 ft. (0 - 1372 M)
Primary Air Opening
1/4" (6 mm) OPEN
FULLY OPEN
High Altitude Installation
When installing this appliance beyond 4500 ft. (1372 M) above sea level, the appliance must be properly de-rated and installed
according to local codes, in the absence of local codes, with the current National Fuel Gas Code, ANSI Z223.1/ NFPA 54, in the US or
Installation Code, CAN/CGA-B149.1, in Canada.