29
Maintenance
Servicing Under Warranty
Before servicing, read the terms and conditions of the Archgard warranty at the back of the manual. Contact the authorized Archgard
dealer where you purchased the appliance from and provide them with details of the problem, along with the initial installation
information (from the front of this manual).
WARNING
Servicing of this appliance must be conducted by a
qualified service technician
. Improper servicing, adjustment or alteration of this
appliance may cause property damage, personal injury or loss of life. All servicing should be conducted with the appliance cold. All
replacement parts must be authorized by Archgard for suitability.
Adjusting Primary Air
NOTE: Fig. 28-A is an example of what a correct or incorrect flame pattern looks like. It is not a true representation of what the
31-DVIE33C-2 will look like in your home environment.
1. The air shutter can be adjusted from the front of the unit while in operation. All adjustments should be made after 20 minutes of
operation.
2.
Locate the Robertson screw below the glass door and left of center. Turn the screw clockwise to give more air ( less yellow flame ).
Turn the screw counter clockwise to give less air (more yellow flame).
Fig. 28-A