Archgard 31-DVIM33C-2 Скачать руководство пользователя страница 22

22

Installation

River Rock Installation

Distribute the rocks evenly around the burner to personal preference. Care must be taken that you DO NOT cover burner ports with any 

of the “large” stone flat surfaces. Keep burner ports clear of blockage:  i.e. flat surfaces of the rocks to create an enjoyable burning fire. 

If the ports are covered it may cause soot build up that will affect the operation and maintenance of your fireplace.

NOTE

Failure to position the parts in accordance with these diagrams or failure to use only parts 

specifically approved with this appliance may result in property damage or personal injury.

Содержание 31-DVIM33C-2

Страница 1: ...is not convertible for use with other gases unless a certified kit is used WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property dam...

Страница 2: ...Instructions 16 Approved Terminations 16 Venting Instructions 999 INS TK 17 Using a Co linear to Coaxial Adapter 18 Optional Wall Switch Or Thermostat 19 Fan Wiring Diagram 19 Vent Restrictor Installa...

Страница 3: ...means that it is less expensive to operate Adjustable Fan Speed Each 31 DVIM33C 2 comes complete with 6 level adjustable speed controlled circulation fan Adjustable Flame The flame aesthetics and heat...

Страница 4: ...a fireplace or stove install an adjustable safety gate to keep toddlers young children and other at risk individuals out of the room and away from hot surfaces Do not store or place combustibles gasol...

Страница 5: ...49 1 in Canada Electrical connections and grounding must conform with local code or current National Electrical code ANSI NFPA No 70 1987 in the US and in Canada the current Canadian Electrical Code C...

Страница 6: ...he rating plate and may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local codes See owner s manual for details This appliance is not convertible...

Страница 7: ...ting screw on each side and swinging the panels out and replacing the screws They can also be disconnected and placed remotely within the limits of the gas connections and electrical wiring making sur...

Страница 8: ...NLY Never attempt to install the appliance into a combustible enclosure If the information in these instructions are not followed exactly a fire or explosion may result causing property damage persona...

Страница 9: ...fireplace flue damper A must be fully blocked open or removed for installation of the gas fireplace insert The fireplace and fireplace chimney must be clean and in good working order and constructed o...

Страница 10: ...se only parts specifically approved with this appliance may result in property damage or personal injury NOTE Mantle depth maybe increased decreased 1 25 4 mm for each 1 25 4 mm change in correspondin...

Страница 11: ...damage or personal injury All specified clearances must be maintained from the top surface of carpeting tile etc Combustible Zone NOTE All specified clearances must be maintained from the top surface...

Страница 12: ...manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa Failure to do so will damage the appliance s gas valve Such da...

Страница 13: ...NUMBERS 31 CKMLP for LP gas and 31 CKMNG for Natural Gas KIT INCLUDES 1 Gas conversion label 303 0128 1 Burner orifice 301 0068 51 51 DMS for LPG 301 0068 33 33 DMS for NG 1 Gas type Label 1 SIT 820...

Страница 14: ...w modulating pressure regulator assembly to the valve using the screws provided in the conversion package Install the LP identification label to the valve found in kit Affix Archgard Manufacturer s la...

Страница 15: ...check the hearth of the fireplace to see if it is level with the front of the fireplace If it is not measure the depth of the hearth Loosen the three screws of the leveling L bracket at the back of t...

Страница 16: ...he appliance to the termination The flue length must be a minimum of 10 3 05 M and a maximum of 40 12 2 M The exhaust vent restrictor provided with this appliance must only be used by installing it on...

Страница 17: ...llar clamp and stove cement provided with the kit DO NOT USE SILICONE 7 Seal and attach the end of the flex liner marked Air Intake to the collar marked Air Intake on the appliance with the collar cla...

Страница 18: ...must conform with the local codes or in the absence of local codes with the current National Fuel Gas Code ANSI Z223 1 NFPA 54 in the US or Installation Code CAN CGA B149 1 in Canada Electrical conne...

Страница 19: ...GA 20 Ft 6 9 M 20 GA 12 Ft 3 65 M 22 GA 9 Ft 2 74 M PILOT ASSEMBLY A ELECTRODE N A B THERMOPILE 308 0056 C PILOT HOOD N A D THERMOCOUPLE 308 0122 Fan Wiring Diagram The fan disc is factory set to clos...

Страница 20: ...ptions available are dependent upon the control panel configuration See Control Panel Locations regarding configura tion Shallow surround options are not available on a unit with Controls Out configur...

Страница 21: ...Fire Bead Installation WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or...

Страница 22: ...ep burner ports clear of blockage i e flat surfaces of the rocks to create an enjoyable burning fire If the ports are covered it may cause soot build up that will affect the operation and maintenance...

Страница 23: ...the bottom of the door lift up on the top of the door until it engages 6 Push down on the top of the door to ensure the door is seated all the way down on the catches 7 Pull the finger rings out and d...

Страница 24: ...STALLED PRIOR TO SCREEN TO AVOID POSSIBLE DAMAGE OR INJURY Identify the top and bottom of the screen Ensure the screen retainer tabs are aligned along the bottom of the screen Insert the hooks in the...

Страница 25: ...me to ensure that the fan is working correctly After the system has been checked and confirmed that the fan is in working order refer to the instructions for FIRST FIRE located in this manual As a rem...

Страница 26: ...26 Operation Operation Lighting Instructions On Rating Plate...

Страница 27: ...dequate combustion and ventilation air Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light...

Страница 28: ...h logs with any liquid While the logs are removed check that all burner openings are not obstructed and it is recommended you use a vacuum cleaner to clean off any dust or lint Vacuum and clean any li...

Страница 29: ...ge personal injury or loss of life All servicing should be conducted with the appliance cold All replacement parts must be authorized by Archgard for suitability Adjusting Primary Air NOTE Fig 28 A is...

Страница 30: ...ed OUT See Below 3 Loosen the set screw inside the tap with a screwdriver 4 Connect a 1 4 6 mm rubber tube to the tap post and a manometer 5 Verify that the readings obtained are within specs as shown...

Страница 31: ...ACCESS FROM THE FRONT 1 Remove the glass door Follow GLASS DOOR REMOVAL instructions within this manual 2 Remove the BURNER MEDIA 3 Remove the pan burner Follow instructions for CHANGING MAIN BURNER...

Страница 32: ...ot immediately after you have shut off the pilot you have to wait 5 minutes for the valve to reset safety system built into the valve 4 Check to see if the pilot flame is large enough to reach and sur...

Страница 33: ...ith flames lifting off the burner at the ends 1 Too much primary air Reduce primary air by closing the primary air shutter During cold temperatures some flame lifting may occur during start up Convect...

Страница 34: ...switch closes the electrical circuit that allows the fan to turn on This is a normal sound Q I hear a ticking cracking or pinging sound when my fireplace is running and after it is turned off A The di...

Страница 35: ...ncludes the items listed below EA 308 0122 Thermocouple EA 308 0056 750 Mv Thermopile EA 733 0027 Pilot Shield EA 831 0051 Burner Assembly Contemporary Type EA RF 305 0024 Replacement Cross flow Fan 1...

Страница 36: ...If you cannot solve the problem contact your Archgard dealer or representative When calling for assistance please have the following information Model of your fireplace Serial Number Place of Purchase...

Страница 37: ...E TAPE CLOSED Model Serial Date Installed Name Address City State Prov ZIP Phone _____ Dealer s Name Address City State Prov ZIP Phone _____ Installer s Name Address City State Prov ZIP Phone _____ Wh...

Страница 38: ...NOTES...

Страница 39: ...NOTES...

Страница 40: ......

Отзывы: