19
Installation
Optional Wall Switch Or Thermostat
If a wall mounted switch or a wall mounted thermostat is desired, Archgard recommends that the device be wired as shown in the
diagram below.
NOTE:
Archgard Industries does not manufacture or sell any type of wall switch or wall thermostat and will not extend warranty to them
Thermostat / wall switch wire table
Recommended Maximum Lead Length for two wires.
Wire Size
Max. Length
14 GA.
50 Ft. (15.24 M)
16 GA.
32 Ft. (9.75 M)
18 GA.
20 Ft. (6.9 M)
20 GA.
12 Ft. (3.65 M)
22 GA.
9 Ft. (2.74 M)
PILOT ASSEMBLY
A
ELECTRODE
N/A
B
THERMOPILE
#308-0056
C
PILOT HOOD
N/A
D
THERMOCOUPLE
#308-0122
Fan Wiring Diagram
The fan disc is factory set to close the circuit to the
fan speed control at 1100 F (430 C) and will turn
off the fan when the temperature falls below 800 F
(270 C).
The 31-DVIM33C-2 comes complete with:
•
Temperature activated fan - (#RF-305-0024)
•
Solid State speed control. - (#305-0013)
•
6ft power cord
NOTE:
This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes,
with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical code, CSA C22.1.