Installation
Venting Instructions
WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result
in carbon monoxide (CO) poisoning and possible death. The appliance must not be connected to a chimney flue serving a
separate solid fuel burning appliance.
CAUTION
Only 3” (76mm) double wall aluminum flex liner and approved vent terminals are to be used for this appliance.
Approved Terminations
Manufacturer
Vertical Termination
Termination Adapter
Archgard
999-INS-TK
N/A
Dura Vent
980 - Co-Axial Cap (requires adapter)
991 - Co-Axial High Wind (requires adapter)
923GK (Co-Axial to Co-Linear)
ICC/Excel
IVT - Co-Linear
VT - Co-Axial (requires adapter)
SVT- Co-Axial (requires adapter)
N/A
CTA or CAA (Co-Axial to Co-Linear)
CTA or CAA (Co-Axial to Co-Linear)
Ameri-vent
DVC - Co-Axial Cap (requires adapter)
DCAT (Co-Axial to Co-Linear)
ATTENTION
NO OTHER VENTING SYSTEM OR COMPONENTS MAY BE USED
. Follow manufacturer instructions for installation of termination.
This appliance is designed for dual 3” (76 mm) double wall aluminum flex liner. The liner must run the entire length of the chimney from
the appliance to the termination.
The flue length must be a minimum of 10’ (3.05 M) and a maximum of 40’ (12.2 M)
The exhaust vent restrictor provided with this appliance must only be used by installing it onto the front of the baffle when
the vent height is over 18’ (5.5 M) if required.
Masonry chimneys may take various contours which the flexible liner will accommodate, however, keep the flexible liner as straight as
possible, avoiding unnecessary bending but at all times keep a minimum of 3” (76 mm) inside bend radius.
The Air Intake Flex Liner must be connected to the inlet air
collars of the termination cap and the appliance.
The Exhaust Flex Liner must be connected to the exhaust collars
of the termination cap and the appliance.
The Air intake and Exhaust connections are marked on the
gas appliance. See picture.
DO NOT REVERSE THESE CONNECTIONS
The 31-DVIM33C-2 requires (2) flexible flue liners:
INLET Collar -
3” (76 mm) diameter
OUTLET Collar -
3” (76 mm) diameter
The 31-DVIE33C-2 showing the Fresh Air Intake and Exhaust
locations. These connections are labeled.
CAUTION
To ensure that the venting is not accidentally obstructed
or punctured, the damper of the host fireplace must
be permanently disabled by either complete removal
of the damper, or by being fully blocked open, for the
installation of a gas fireplace insert.