27-DVIM22
19
If a wall mounted switch or a wall mounted thermostat is desired, Archgard recommends that the device be
wired as shown in the diagram below.
NOTE
: Archgard Industries does not manufacture or sell any type of wall switch or wall thermostat and will not
extend warranty to them
OPTIONAL WALL SWITCH OR THERMOSTAT
A
ELECTRODE
N/A
B
THERMOPILE
# 308-0056
C
PILOT HOOD
N/A
D
THERMOCOUPLE
# 308--0122
PILOT ASSEMBLY
Thermostat/wall switch wire table
Recommended max length for two wires
.
Wire Size
Max. Length
14 GA.
50’ (15.24 M)
16 GA.
32’ (9.75 M)
18 GA.
20’ (6.9 M)
20 GA.
12’ (3.65 M)
22 GA.
9’ (2.74 M)
M
SPEED
110
F (43ºC) N.O.
THERMAL SNAP
CONVECTION BLOWER
LINE
GROUND
NEUTRAL
To Appliance
120
VAC
white
black
SPEED
LINE
GROUND
NEUTRAL
1
1
0º
F (43
º
C)
N.O.
CONVECTION
BLOWER
white
black
green
OPTIONAL
REMOTE SWITCH
ON / OFF
SWITCH
WIRE TO
PIEZO
B
A
C
D
SUPPLY TUBE
THERMOCOUPLE
T
THT
TH
FAN WIRING DIAGRAM
The 27-DVIM22 comes complete with:
Temperature activated fan - (#RF-305-0024)
Solid State speed control. - (#305-0013)
6ft power cord
NOTE:
This appliance, when installed, must be electrically grounded in accordance with local codes or, in the
absence of local codes, with the
National Electrical Code, ANSI/NFPA 70
, or the
Canadian Electrical code,
CSA C22.1.
The fan disc is factory set to close
the circuit to the fan speed control at
110
0
F (43
0
C) and will turn off the
fan when the temperature falls below
80
0
F (27
0
C).
Fig. 19-B
Fig. 19-A