Archgard 22-DVI24N-3 Скачать руководство пользователя страница 39

22-DVI24N-3                                 39 

FREQUENTLY ASKED QUESTIONS

 

Listed below are some frequently asked questions regarding Archgard Gas Fireplaces. If you have 

questions that are not listed below, or are not answered in this manual, please contact your Authorized 

Archgard Dealer.

 

 

Q.

 My glass has a condensation 

fog

” 

when the appliance is first lit. 

 

A.

 Condensation is normal and will disappear in a few minutes after the glass is heated.

 

 

Q. 

I have a white 

film

” 

on my glass. What is the best way to clean the inside of the glass. 

 

A. 

Frequent cleaning of your glass is recommended. Archgard recommends using a good quality 

gas 

fireplace

” 

glass cleaner that is available at all authorized dealers. Do not use abrasive materials, and do 

not clean the glass or the appliance when the unit is hot. 

 

 

Q. 

How do I care for my gold plated trims. 

 

A. 

Archgard recommends a cleaning with a damp cloth. DO NOT use chemical cleaners as they may 

harm the finish, and void your warranty.  NOTE: If the top louvers, or top overlay starts to discolor, check 

the door gasket seal and replace if necessary. 

 

 

Q. 

My fan/blower makes a 

whirring

” 

or 

humming

” 

noise. 

 

A. 

Your Archgard gas appliance uses a powerful fan to push heated air into your room. It is not unusual 

to hear a 

humming

” 

noise when your fan is running. Note: the sound will change depending on the 

setting that your fan speed control is set at.

 

 

Q. 

I hear a 

click

” 

when my fan system activates. 

 

A. 

When your appliance reaches temperature, it will activate the THERMODISC 

fan switch

”. 

The switch 

closes the electrical circuit that allows the fan to turn on. This is a normal sound. 

 

 

Q. 

I hear a 

ticking

”, “

cracking

” 

or 

pinging

” 

sound when my fireplace is running, and after it is turned off.

 

A. 

The different gauges of steel used to manufacture your fireplace will expand and contract at different 

rates when your fireplace is on, and will continued as your fireplace completes its heating function. You 

will likely hear these same sounds more on start up and shut down. This is normal for steel fireplaces.

 

 

Q. 

When my appliance is OFF and my pilot light is lit, I hear a 

whisper

” 

sound.

 

A. 

The lit pilot can make a small noise. Sometimes in extreme wind conditions you may be able to hear 

air entering into the firebox chamber. 

 

 

Q. 

I hear a 

click" when my main burner turns ON or OFF.

 

A. 

Your Gas Control Valve will make a clicking sound when it opens to allow gas to flow to the main 

burner. This is a normal part of the operating system.  

 

 

Q. 

Can I burn wood and other materials in my gas fireplace. 

 

A. 

No! Burning anything other than natural or LP gas in a gas fireplace or stove will create a potential fire 

hazard and present a danger to your home and its occupants. Only burn the gas fuel for which the unit 

was originally designed.

 

 

Q. 

Can I shut my pilot off in the summer?

 

A. 

You will save energy by turning off the pilot light if you are not using your appliance for the hot 

summer months.  Remember to relight it before you want to use the appliance for the first time in the fall. 

Refer to your owners manual for lighting instructions.

 

 

Q. 

Can I position my gas logs in a different fashion or use a different log set?

 

A. 

No. Your gas fireplace is an engineered system that includes the firebox, burner, logs, venting and 

options which are tested and listed by CSA. Changing any specifications or placement of the logs could 

void your manufacturer's warranty, and possible even your homeowner's warranty.

 

Содержание 22-DVI24N-3

Страница 1: ...anuals available through your local dealer or visit our website at www archgard com Les manuels d installation en anglais et en fran ais son disponibles chez votre d taillant local ou en visitant notr...

Страница 2: ...ation 21 First Fire and Lighting Instructions CAUTION 22 Lighting Instructions on Rating Plate 23 Glass Door Removal If Your Glass Should Break 24 Safety Barrier Installation 25 Optional Bay Door Inst...

Страница 3: ...can be adjusted to suit the owner s liking and heating needs Solid Construction The 22 DVI24N 3 is mainly constructed of 16 and 18 gauge galvanized and aluminized coated steel for long life and durab...

Страница 4: ...children and other at risk individuals out of the room and away from hot surfaces Do not store or place combustibles gasoline and other flammable vapors and liquids near the appliance Clothing or othe...

Страница 5: ...anada Electrical connections and grounding must conform with local code or in the absence of local codes with the National Electrical Code ANSI NFPA 70 in the US and in Canada the current Canadian Ele...

Страница 6: ...22 DVI24N 3 6 RATING PLATE SAMPLE...

Страница 7: ...fireplace in which the gas fireplace insert is to be installed is prohibited If the factory built fireplace has no gas access hole s provided an access hole of 1 1 2 37 5 mm or less may be drilled th...

Страница 8: ...ustible mantle allowed in shaded area Mantle extension maybe increased 1 25 mm for each additional 1 25 mm increase in clearance height Example If using a 5 127 mm shelf reduce the minimum height to 3...

Страница 9: ...gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa Failure to...

Страница 10: ...rheostat installed and wired to a three prong grounding plug for your protection against shock hazard and should be plugged in directly into a properly grounded three prong receptacle Do not cut or re...

Страница 11: ...imneys may take various contours which the flexible liner will accommodate however keep the flexible liner as straight as possible avoiding unnecessary bending but at all times keep a minimum of 3 76...

Страница 12: ...trictor 1 for vent height installations over 20 6 1 Meters use restrictor 2 Seal and attach the end of the flex liner marked Exhaust to the collar marked Exhaust on the appliance with the collar clamp...

Страница 13: ...a Electrical connections and grounding must conform with local code or current National Electrical code ANSI NFPA No 70 1987 in the US and in Canada the current Canadian Electrical Code CSA C22 1 The...

Страница 14: ...Only Trim kit s supplied by the manufacturer should be used in the installation of this appliance 1 Using the trim clips provided join the left side trim which has a notch cut for rocker switch to the...

Страница 15: ...any wall switch or wall thermostat and will not extend warranty to them OPTIONAL WALL SWITCH OR THERMOSTAT Thermostat wall switch wire table Recommended Maximum Lead Length for two wires Wire Size Max...

Страница 16: ...may cause sooting on the internal parts and glass and will not be covered under warranty Do not use broken or damaged logs Locate the embers logs and grate and place them on their prospective locatio...

Страница 17: ...t on the locater pins as shown The back of the log should rest on the log rest to allow secondary air to flow under the log Step 2 Locate the back log so the left side of the log is on the locater pin...

Страница 18: ...NT Continued Step 3 Locate the left log and place it on the two left locater pins so the detail is facing forward Step 4 Locate the center log and place it on the two center locater pins so the burnt...

Страница 19: ...sure it is not blocking any ports The top of the log should rest on the rear log and the branch should rest on the center log Step 6 Locate the top left log and place it so the burnt portion faces to...

Страница 20: ...that no Damage has occurred inside the package Please report any damage immediately to your Authorized Archgard Dealer Gas and vent connections must be made before installing the brick and reflective...

Страница 21: ...1 Perform leak tests of supply line gas control valve supply line from gas control valve and pilot assembly 2 Clocking the appliance to ensure the correct firing rate see page 9 of this manual 3 If r...

Страница 22: ...spect the appliance and to replace any part of the control system and any gas control which has been under water WARNING If you do not follow these instructions exactly a fire or explosion may result...

Страница 23: ...22 DVI24N 3 23 LIGHTING INSTRUCTIONS ON RATING PLATE...

Страница 24: ...dure of Removing the Glass Door IF YOUR GLASS BREAKS WARNING Do not operate appliance with the glass front cracked or broken Replacement of the glass should be done by a licensed or qualified service...

Страница 25: ...22 DVI24N 3 25 22 DVI24N 3 Screen Barrier Installation and Removal If the barrier becomes damaged the barrier shall be replaced with the manufacturer s barrier for this appliance...

Страница 26: ...instructions 1 Remove the upper grilles by pulling the assembly forward 2 Remove the lower grilles by removing the four hex head mounting screws that secure the brass hinges to the unit 3 Discard the...

Страница 27: ...tive Pilot will not remain on after being lit 1 Press the control knob all the way in at the pilot indicator 2 Hold the control knob in for a longer period of time 3 If you are trying to re light the...

Страница 28: ...Check wire connections Expansion from heat affects a loose connection Sooty deposits on the glass door 1 If the flame is yellow and lazy check for lint etc around primary air shutter Increase primary...

Страница 29: ...s recommended you use a vacuum cleaner to clean off any dust or lint Vacuum and clean any lint accumulations or debris in the firebox on the burners on the pilot at the primary air opening on the conv...

Страница 30: ...personal injury or loss of life All servicing should be conducted with the appliance cold All replacement parts must be authorized by Archgard for suitability 1 Open the lower grills 2 Unscrew the 2 s...

Страница 31: ...e Follow ADJUSTING PRIMARY AIR instructions within this manual for reassembly 3 Remove the logs See LOG PLACEMENT for instructions 4 Remove the brick liners and remove the screws holding the burner pa...

Страница 32: ...INLET AND OUTLET GAS PRESSURE CHECKING AND ADJUSTING PILOT Fig 1 CONVERTIBLE PILOT ORIFICE The pilot assembly is convertible to the type of gas being used simply unscrew the body by using a 7 16 11 m...

Страница 33: ...al 2 Remove the log set Follow LOG PLACEMENT instructions within this manual 3 Loosen the adjustment wing nut and slide the air shutter to the left Follow ADJUSTING PRIMARY AIR instructions within thi...

Страница 34: ...ropane Gas 1 EA G 301 6007 Orifice holder 2 EA H 620 0024 Aluminum Pilot Box 1 EA I 314 0127 Gasket Ceramic Paper 1 EA J 314 0127 Gasket Ceramic Paper 1 EA K 308 0093 Pilot Assembly Convertible NG LP...

Страница 35: ...Log Right 1 EA 310 6222 2 Log Rear 1 EA 310 6222 3 Log Left 1 EA 310 6222 4 Log Center 1 EA 310 6222 5 Log Top Right 1 EA 310 6222 6 Log Top Left 1 EA 310 6222 Log set 6pc pinned 1 EA 841 0051 Pan Bu...

Страница 36: ...0131 Air Shutter Gasket 2 IN 800 0031 Wiring Harness assembly for On Off Rocker Switch 1 EA 305 0019 On Off Rocker Switch 1 EA Fan Components 305 0012 Power Cord 8 2 43 M 1 EA 305 0013 Fan Speed Cont...

Страница 37: ...al Gold Bay Window Strips Full Set Includes top bottom trim pieces 1 EA Optional Surround Trims 22 TKSB Black Trim for SKBAB SKCAB surround 1 SET 22 TKLB Black Trim for SKLB surround 1 SET 22 TKSG Gol...

Страница 38: ...contact your Archgard dealer or representative When calling for assistance please have the following information Model of your fireplace Serial Number Place of Purchase Date of Purchase Problem Descri...

Страница 39: ...king cracking or pinging sound when my fireplace is running and after it is turned off A The different gauges of steel used to manufacture your fireplace will expand and contract at different rates wh...