Archgard 22-DVI24N-3 Скачать руководство пользователя страница 3

INTRODUCTION

 

Congratulations on choosing an Archgard Gas Fireplace!

 

 

The 22

-

DVI24N

-

3 Direct Vent Insert is one of the most advanced Direct Vent Insert heaters 

available today. It is solidly designed using the latest technology and manufactured to the 

highest quality. It is our aim to provide you with an appliance for many trouble

-

free years of 

reliable service. 

 

 

Some of the many features of your 22

-

DVI24N

-

3 Direct Vent Insert are:

 

 

• 

Heater Classification.  The 22

-

DVI24N

-

3 is classified as a heating appliance.  

 

 Therefore, it uses Direct Vent safety technology and it is suitable for continuously operated 

zone heating.

 

• 

High Efficiency. The 22

-

DVI24N

-

3 has one of the highest efficiencies of any   Direct Vent 

gas insert, which means that it is less expensive  to operate.

 

• 

Adjustable Fan Speed.  Each 22

-

DVI24N

-

3 insert comes complete with a heat

-

 activated 

circulation fan with a fully adjustable speed control.

 

• 

Adjustable Flame. The flame aesthetics and heat output can be adjusted to suit  the 

owner

s liking and heating needs.

 

• 

Solid Construction. The 22

-

DVI24N

-

3 is mainly constructed of 16 and 18 gauge   

galvanized and aluminized coated steel for long life and   durability.

 

• 

Optional Accessories. Check with your Authorized Archgard Dealer for a full    

complement of decorative accessories to suit your home

s   décor and your tastes. Some 

of the accessories available   are: 24K Gold Overlay (for the flat window), a variety of   

surrounds (faceplates) with gold, black or pewter trims and   an overlay bay window that 

simply attaches to the front of   your fireplace while leaving the flat glass door in place.  

 

• 

Millivolt Control System. The 22

-

DVI24N

-

3 uses a gas control valve that is ready for  an 

optional wall thermostat, or a hand

-

held 

wireless

” 

remote  control.

 

We recommend you record the following information:

 

 

Fireplace Model Number:  

22-DVI24N-3

 

 Serial Number:   

 

 

Date of Installation:   

 

 

Type of Gas Used by the Fireplace:     Natural Gas     Propane

 

 

Dealer

s Name & Address:  

 

 

 

 

 

 

Dealer

s Phone Number: 

 

 

Please complete and submit the warranty registration card included in the back of this manual or by visiting us at:

 

www.archgard.com/warranty

-

registration

 

Содержание 22-DVI24N-3

Страница 1: ...anuals available through your local dealer or visit our website at www archgard com Les manuels d installation en anglais et en fran ais son disponibles chez votre d taillant local ou en visitant notr...

Страница 2: ...ation 21 First Fire and Lighting Instructions CAUTION 22 Lighting Instructions on Rating Plate 23 Glass Door Removal If Your Glass Should Break 24 Safety Barrier Installation 25 Optional Bay Door Inst...

Страница 3: ...can be adjusted to suit the owner s liking and heating needs Solid Construction The 22 DVI24N 3 is mainly constructed of 16 and 18 gauge galvanized and aluminized coated steel for long life and durab...

Страница 4: ...children and other at risk individuals out of the room and away from hot surfaces Do not store or place combustibles gasoline and other flammable vapors and liquids near the appliance Clothing or othe...

Страница 5: ...anada Electrical connections and grounding must conform with local code or in the absence of local codes with the National Electrical Code ANSI NFPA 70 in the US and in Canada the current Canadian Ele...

Страница 6: ...22 DVI24N 3 6 RATING PLATE SAMPLE...

Страница 7: ...fireplace in which the gas fireplace insert is to be installed is prohibited If the factory built fireplace has no gas access hole s provided an access hole of 1 1 2 37 5 mm or less may be drilled th...

Страница 8: ...ustible mantle allowed in shaded area Mantle extension maybe increased 1 25 mm for each additional 1 25 mm increase in clearance height Example If using a 5 127 mm shelf reduce the minimum height to 3...

Страница 9: ...gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa Failure to...

Страница 10: ...rheostat installed and wired to a three prong grounding plug for your protection against shock hazard and should be plugged in directly into a properly grounded three prong receptacle Do not cut or re...

Страница 11: ...imneys may take various contours which the flexible liner will accommodate however keep the flexible liner as straight as possible avoiding unnecessary bending but at all times keep a minimum of 3 76...

Страница 12: ...trictor 1 for vent height installations over 20 6 1 Meters use restrictor 2 Seal and attach the end of the flex liner marked Exhaust to the collar marked Exhaust on the appliance with the collar clamp...

Страница 13: ...a Electrical connections and grounding must conform with local code or current National Electrical code ANSI NFPA No 70 1987 in the US and in Canada the current Canadian Electrical Code CSA C22 1 The...

Страница 14: ...Only Trim kit s supplied by the manufacturer should be used in the installation of this appliance 1 Using the trim clips provided join the left side trim which has a notch cut for rocker switch to the...

Страница 15: ...any wall switch or wall thermostat and will not extend warranty to them OPTIONAL WALL SWITCH OR THERMOSTAT Thermostat wall switch wire table Recommended Maximum Lead Length for two wires Wire Size Max...

Страница 16: ...may cause sooting on the internal parts and glass and will not be covered under warranty Do not use broken or damaged logs Locate the embers logs and grate and place them on their prospective locatio...

Страница 17: ...t on the locater pins as shown The back of the log should rest on the log rest to allow secondary air to flow under the log Step 2 Locate the back log so the left side of the log is on the locater pin...

Страница 18: ...NT Continued Step 3 Locate the left log and place it on the two left locater pins so the detail is facing forward Step 4 Locate the center log and place it on the two center locater pins so the burnt...

Страница 19: ...sure it is not blocking any ports The top of the log should rest on the rear log and the branch should rest on the center log Step 6 Locate the top left log and place it so the burnt portion faces to...

Страница 20: ...that no Damage has occurred inside the package Please report any damage immediately to your Authorized Archgard Dealer Gas and vent connections must be made before installing the brick and reflective...

Страница 21: ...1 Perform leak tests of supply line gas control valve supply line from gas control valve and pilot assembly 2 Clocking the appliance to ensure the correct firing rate see page 9 of this manual 3 If r...

Страница 22: ...spect the appliance and to replace any part of the control system and any gas control which has been under water WARNING If you do not follow these instructions exactly a fire or explosion may result...

Страница 23: ...22 DVI24N 3 23 LIGHTING INSTRUCTIONS ON RATING PLATE...

Страница 24: ...dure of Removing the Glass Door IF YOUR GLASS BREAKS WARNING Do not operate appliance with the glass front cracked or broken Replacement of the glass should be done by a licensed or qualified service...

Страница 25: ...22 DVI24N 3 25 22 DVI24N 3 Screen Barrier Installation and Removal If the barrier becomes damaged the barrier shall be replaced with the manufacturer s barrier for this appliance...

Страница 26: ...instructions 1 Remove the upper grilles by pulling the assembly forward 2 Remove the lower grilles by removing the four hex head mounting screws that secure the brass hinges to the unit 3 Discard the...

Страница 27: ...tive Pilot will not remain on after being lit 1 Press the control knob all the way in at the pilot indicator 2 Hold the control knob in for a longer period of time 3 If you are trying to re light the...

Страница 28: ...Check wire connections Expansion from heat affects a loose connection Sooty deposits on the glass door 1 If the flame is yellow and lazy check for lint etc around primary air shutter Increase primary...

Страница 29: ...s recommended you use a vacuum cleaner to clean off any dust or lint Vacuum and clean any lint accumulations or debris in the firebox on the burners on the pilot at the primary air opening on the conv...

Страница 30: ...personal injury or loss of life All servicing should be conducted with the appliance cold All replacement parts must be authorized by Archgard for suitability 1 Open the lower grills 2 Unscrew the 2 s...

Страница 31: ...e Follow ADJUSTING PRIMARY AIR instructions within this manual for reassembly 3 Remove the logs See LOG PLACEMENT for instructions 4 Remove the brick liners and remove the screws holding the burner pa...

Страница 32: ...INLET AND OUTLET GAS PRESSURE CHECKING AND ADJUSTING PILOT Fig 1 CONVERTIBLE PILOT ORIFICE The pilot assembly is convertible to the type of gas being used simply unscrew the body by using a 7 16 11 m...

Страница 33: ...al 2 Remove the log set Follow LOG PLACEMENT instructions within this manual 3 Loosen the adjustment wing nut and slide the air shutter to the left Follow ADJUSTING PRIMARY AIR instructions within thi...

Страница 34: ...ropane Gas 1 EA G 301 6007 Orifice holder 2 EA H 620 0024 Aluminum Pilot Box 1 EA I 314 0127 Gasket Ceramic Paper 1 EA J 314 0127 Gasket Ceramic Paper 1 EA K 308 0093 Pilot Assembly Convertible NG LP...

Страница 35: ...Log Right 1 EA 310 6222 2 Log Rear 1 EA 310 6222 3 Log Left 1 EA 310 6222 4 Log Center 1 EA 310 6222 5 Log Top Right 1 EA 310 6222 6 Log Top Left 1 EA 310 6222 Log set 6pc pinned 1 EA 841 0051 Pan Bu...

Страница 36: ...0131 Air Shutter Gasket 2 IN 800 0031 Wiring Harness assembly for On Off Rocker Switch 1 EA 305 0019 On Off Rocker Switch 1 EA Fan Components 305 0012 Power Cord 8 2 43 M 1 EA 305 0013 Fan Speed Cont...

Страница 37: ...al Gold Bay Window Strips Full Set Includes top bottom trim pieces 1 EA Optional Surround Trims 22 TKSB Black Trim for SKBAB SKCAB surround 1 SET 22 TKLB Black Trim for SKLB surround 1 SET 22 TKSG Gol...

Страница 38: ...contact your Archgard dealer or representative When calling for assistance please have the following information Model of your fireplace Serial Number Place of Purchase Date of Purchase Problem Descri...

Страница 39: ...king cracking or pinging sound when my fireplace is running and after it is turned off A The different gauges of steel used to manufacture your fireplace will expand and contract at different rates wh...

Страница 40: ...NE Model 22 DVI24N 3 Serial Date Installed Name Address City State Prov ZIP Phone _____ Dealer s Name Address City State Prov ZIP Phone _____ Installer s Name Address City State Prov ZIP Phone _____ W...

Страница 41: ...NOTES...

Страница 42: ...NOTES...

Страница 43: ...NOTES...

Страница 44: ...Archgard Industries Ltd 7116 Beatty Drive Mission B C V2V 6B4 Canada Website www archgard com...

Отзывы: