TROUBLESHOOTING

 

SYMPTOM

 

ACTION

 

Pilot will not light after 

pressing the sparker many 

times.

 

1. When lighting the appliance for the first time after installation or after 

servicing, there is air in the gas line. It takes a while for all of the air to 

purge out of the pilot before gas can reach the pilot and ignite. 

Remove the glass door and try lighting the pilot many times to purge 

the air.

 

2. Check to make sure the gas supply to the appliance is turned on and 

there is adequate gas supply pressure to the appliance.

 

3. Check for sparks between the spark electrode and the pilot head when 

the sparker is pressed. If there are no sparks:

 

a. Check for broken or poor connection from the sparker to the 

electrode. 

 

b. Check for the spark shorting or arcing at other locations. 

 

c. Check for defective sparker.

 

d. Check for defective spark electrode.

 

4. With the door removed, try lighting the pilot with a match.

 

a. If air is blowing on the flame of the match, hold the control knob in 

at the 

PILOT

’ 

setting until all the air is purged out of the line.

 

b. If there is no gas or air coming out of the pilot and there is gas 

pressure to the appliance, the pilot orifice may be blocked or the 

gas valve may be defective.

 

Pilot will not remain on after 

being lit.

 

1. Press the control knob all the way in (at the 

pilot

” 

indicator). 

 

2. Hold the control knob in for a longer period of time.

 

3. If you are trying to re

-

light the pilot immediately after you have shut

-

off 

the pilot, you have to wait 5 minutes for the valve to reset. (safety 

system built into the valve) 

 

4. Check to see if the pilot flame is large enough to reach and surround 

the thermocouple. If the flame is too small, check for correct gas 

supply pressure. If pressure is good, adjust the pilot flame size with 

the adjustment screw on the valve. If the flame cannot be adjusted, 

there might be some debris obstructing the pilot orifice, or a wrong 

size pilot orifice.

 

5. Check for poor connection of the thermocouple to the valve.

 

6. Check for proper millivolts of the thermocouple. The thermocouple 

should generate at least 20 mV or it is defective.

 

7. Check for defective gas valve.

 

The main burner does not turn 

on with the pilot lit.

 

1. Check to make sure the control knob is turned to the 

ON

’ 

position.

 

2. Allow enough time for the pilot to heat up the thermopile to generate 

sufficient voltage to activate the valve.

 

Please check to make sure the instructions are followed exactly before attempting 

troubleshooting of the appliance.

 

 

WARNING: 

Troubleshooting and servicing of gas and electrical devices of the 

appliance should only be conducted by a qualified service technician.

 

Содержание 22-DVI24N-3

Страница 1: ...anuals available through your local dealer or visit our website at www archgard com Les manuels d installation en anglais et en fran ais son disponibles chez votre d taillant local ou en visitant notr...

Страница 2: ...ation 21 First Fire and Lighting Instructions CAUTION 22 Lighting Instructions on Rating Plate 23 Glass Door Removal If Your Glass Should Break 24 Safety Barrier Installation 25 Optional Bay Door Inst...

Страница 3: ...can be adjusted to suit the owner s liking and heating needs Solid Construction The 22 DVI24N 3 is mainly constructed of 16 and 18 gauge galvanized and aluminized coated steel for long life and durab...

Страница 4: ...children and other at risk individuals out of the room and away from hot surfaces Do not store or place combustibles gasoline and other flammable vapors and liquids near the appliance Clothing or othe...

Страница 5: ...anada Electrical connections and grounding must conform with local code or in the absence of local codes with the National Electrical Code ANSI NFPA 70 in the US and in Canada the current Canadian Ele...

Страница 6: ...22 DVI24N 3 6 RATING PLATE SAMPLE...

Страница 7: ...fireplace in which the gas fireplace insert is to be installed is prohibited If the factory built fireplace has no gas access hole s provided an access hole of 1 1 2 37 5 mm or less may be drilled th...

Страница 8: ...ustible mantle allowed in shaded area Mantle extension maybe increased 1 25 mm for each additional 1 25 mm increase in clearance height Example If using a 5 127 mm shelf reduce the minimum height to 3...

Страница 9: ...gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa Failure to...

Страница 10: ...rheostat installed and wired to a three prong grounding plug for your protection against shock hazard and should be plugged in directly into a properly grounded three prong receptacle Do not cut or re...

Страница 11: ...imneys may take various contours which the flexible liner will accommodate however keep the flexible liner as straight as possible avoiding unnecessary bending but at all times keep a minimum of 3 76...

Страница 12: ...trictor 1 for vent height installations over 20 6 1 Meters use restrictor 2 Seal and attach the end of the flex liner marked Exhaust to the collar marked Exhaust on the appliance with the collar clamp...

Страница 13: ...a Electrical connections and grounding must conform with local code or current National Electrical code ANSI NFPA No 70 1987 in the US and in Canada the current Canadian Electrical Code CSA C22 1 The...

Страница 14: ...Only Trim kit s supplied by the manufacturer should be used in the installation of this appliance 1 Using the trim clips provided join the left side trim which has a notch cut for rocker switch to the...

Страница 15: ...any wall switch or wall thermostat and will not extend warranty to them OPTIONAL WALL SWITCH OR THERMOSTAT Thermostat wall switch wire table Recommended Maximum Lead Length for two wires Wire Size Max...

Страница 16: ...may cause sooting on the internal parts and glass and will not be covered under warranty Do not use broken or damaged logs Locate the embers logs and grate and place them on their prospective locatio...

Страница 17: ...t on the locater pins as shown The back of the log should rest on the log rest to allow secondary air to flow under the log Step 2 Locate the back log so the left side of the log is on the locater pin...

Страница 18: ...NT Continued Step 3 Locate the left log and place it on the two left locater pins so the detail is facing forward Step 4 Locate the center log and place it on the two center locater pins so the burnt...

Страница 19: ...sure it is not blocking any ports The top of the log should rest on the rear log and the branch should rest on the center log Step 6 Locate the top left log and place it so the burnt portion faces to...

Страница 20: ...that no Damage has occurred inside the package Please report any damage immediately to your Authorized Archgard Dealer Gas and vent connections must be made before installing the brick and reflective...

Страница 21: ...1 Perform leak tests of supply line gas control valve supply line from gas control valve and pilot assembly 2 Clocking the appliance to ensure the correct firing rate see page 9 of this manual 3 If r...

Страница 22: ...spect the appliance and to replace any part of the control system and any gas control which has been under water WARNING If you do not follow these instructions exactly a fire or explosion may result...

Страница 23: ...22 DVI24N 3 23 LIGHTING INSTRUCTIONS ON RATING PLATE...

Страница 24: ...dure of Removing the Glass Door IF YOUR GLASS BREAKS WARNING Do not operate appliance with the glass front cracked or broken Replacement of the glass should be done by a licensed or qualified service...

Страница 25: ...22 DVI24N 3 25 22 DVI24N 3 Screen Barrier Installation and Removal If the barrier becomes damaged the barrier shall be replaced with the manufacturer s barrier for this appliance...

Страница 26: ...instructions 1 Remove the upper grilles by pulling the assembly forward 2 Remove the lower grilles by removing the four hex head mounting screws that secure the brass hinges to the unit 3 Discard the...

Страница 27: ...tive Pilot will not remain on after being lit 1 Press the control knob all the way in at the pilot indicator 2 Hold the control knob in for a longer period of time 3 If you are trying to re light the...

Страница 28: ...Check wire connections Expansion from heat affects a loose connection Sooty deposits on the glass door 1 If the flame is yellow and lazy check for lint etc around primary air shutter Increase primary...

Страница 29: ...s recommended you use a vacuum cleaner to clean off any dust or lint Vacuum and clean any lint accumulations or debris in the firebox on the burners on the pilot at the primary air opening on the conv...

Страница 30: ...personal injury or loss of life All servicing should be conducted with the appliance cold All replacement parts must be authorized by Archgard for suitability 1 Open the lower grills 2 Unscrew the 2 s...

Страница 31: ...e Follow ADJUSTING PRIMARY AIR instructions within this manual for reassembly 3 Remove the logs See LOG PLACEMENT for instructions 4 Remove the brick liners and remove the screws holding the burner pa...

Страница 32: ...INLET AND OUTLET GAS PRESSURE CHECKING AND ADJUSTING PILOT Fig 1 CONVERTIBLE PILOT ORIFICE The pilot assembly is convertible to the type of gas being used simply unscrew the body by using a 7 16 11 m...

Страница 33: ...al 2 Remove the log set Follow LOG PLACEMENT instructions within this manual 3 Loosen the adjustment wing nut and slide the air shutter to the left Follow ADJUSTING PRIMARY AIR instructions within thi...

Страница 34: ...ropane Gas 1 EA G 301 6007 Orifice holder 2 EA H 620 0024 Aluminum Pilot Box 1 EA I 314 0127 Gasket Ceramic Paper 1 EA J 314 0127 Gasket Ceramic Paper 1 EA K 308 0093 Pilot Assembly Convertible NG LP...

Страница 35: ...Log Right 1 EA 310 6222 2 Log Rear 1 EA 310 6222 3 Log Left 1 EA 310 6222 4 Log Center 1 EA 310 6222 5 Log Top Right 1 EA 310 6222 6 Log Top Left 1 EA 310 6222 Log set 6pc pinned 1 EA 841 0051 Pan Bu...

Страница 36: ...0131 Air Shutter Gasket 2 IN 800 0031 Wiring Harness assembly for On Off Rocker Switch 1 EA 305 0019 On Off Rocker Switch 1 EA Fan Components 305 0012 Power Cord 8 2 43 M 1 EA 305 0013 Fan Speed Cont...

Страница 37: ...al Gold Bay Window Strips Full Set Includes top bottom trim pieces 1 EA Optional Surround Trims 22 TKSB Black Trim for SKBAB SKCAB surround 1 SET 22 TKLB Black Trim for SKLB surround 1 SET 22 TKSG Gol...

Страница 38: ...contact your Archgard dealer or representative When calling for assistance please have the following information Model of your fireplace Serial Number Place of Purchase Date of Purchase Problem Descri...

Страница 39: ...king cracking or pinging sound when my fireplace is running and after it is turned off A The different gauges of steel used to manufacture your fireplace will expand and contract at different rates wh...

Страница 40: ...NE Model 22 DVI24N 3 Serial Date Installed Name Address City State Prov ZIP Phone _____ Dealer s Name Address City State Prov ZIP Phone _____ Installer s Name Address City State Prov ZIP Phone _____ W...

Страница 41: ...NOTES...

Страница 42: ...NOTES...

Страница 43: ...NOTES...

Страница 44: ...Archgard Industries Ltd 7116 Beatty Drive Mission B C V2V 6B4 Canada Website www archgard com...

Отзывы: