Archer VR3 Скачать руководство пользователя страница 1

Archer

 

Instruments,

 

LLC

                                                                                                                     

www.archerinstruments.com

 

 

 

Model VR3 Vacuum Regulator 

Installation, Operation & Maintenance 

 

General:    

The Archer Instruments Model VR3 vacuum regulator is designed for use in 

vacuum gas feed systems. The VR3 incorporates an integral graduated meter tube, which 
provides a local indication of gas flow rate. The VR3 can be provided with or without an 
integral rate control valve. *Note: For systems using an automatic switchover module, the 
VR3 vacuum regulator should be plugged (rate valve removed) as the integral rate valve 
can cause improper switchover operation.

  

 
Safety:
  

   When working with chlorine, always use caution and follow applicable safety 

procedures. General safety considerations: 
 
* Store chlorine separately from ammonia.  
 
* When using chlorine, avoid locations that expose the cylinder and equipment to direct 
sunlight. 
 
* Do not apply heater or heat source directly to chlorine cylinders. 
 
* 150lb (upright) cylinders: Always keep cylinders upright and ensure the steel valve cap is 
in place when moving cylinders. Once cylinder is in place, a safety chain should be used to 
secure the cylinder. 
 
* Ton Containers: Use appropriate handling equipment when moving ton containers. When 
readying ton container for use, ensure valves are aligned vertically. The top valve accesses 
gaseous chlorine and the bottom valve accesses liquid chlorine. The bottom valve should 
never be touched unless your system employs a chlorine heat exchanger (evaporator) 
designed expressly for use with liquid chlorine. When drawing gas from ton containers an 
appropriate ton container adapter & drip leg must be used (also available from Archer 
Instruments).

 

 

Содержание VR3

Страница 1: ...ine separately from ammonia When using chlorine avoid locations that expose the cylinder and equipment to direct sunlight Do not apply heater or heat source directly to chlorine cylinders 150lb uprigh...

Страница 2: ...chlorine cylinder valve 4 Holding the VR3 vacuum regulator upright settle it over the cylinder valve and fit the inlet capsule into the cylinder valve outlet port 5 Using a 3 8 wrench tighten the yoke...

Страница 3: ...d with a rate valve adjust the rate valve knob until the desired feed rate is indicated on the graduated meter tube Maintaining the VR3 Recommended Maintenance Frequency Archer Instruments recommends...

Страница 4: ...rom the diaphragm assembly by hand or if necessary by using a pair of pliers But it is generally not necessary to remove this pin for routine maintenance Simply replace the OA VIT 006 o ring 7 The dia...

Страница 5: ...at VRA 110 can be removed by pressing it up and through the inlet capsule The inlet valve seat is a maintenance part and once removed should never be reused f Carefully clean the inlet capsule seal pl...

Страница 6: ...A X Meter Gasket 1 2 3 4 10 25 100 250 PPD 34 1 VRA 141 Inlet Capsule 12 1 MTA 108 XXX Meter Tube with ball stops 004 010 025 050 100 250 PPD 35 1 VRA 142 Retainer Clip 13 1 VRA 104 Pin Guide 36 1 VRA...

Страница 7: ...Inlet Spring Holder 12 1 SPA 100 Vent Spring 36 1 VRA 183 Spring Retainer 13 1 MGA 115 Bottom Meter Gasket 37 1 VRA 111 Vent Plug 14 3 OA VIT 212 O Ring 38 1 OA VIT 009 O Ring 15 1 MIA 232 Meter Inlet...