WWW.ARCBRO.COM
Arc voltage disabling distance near end point
----- The machining path is usually a closed curve. At the end of
machining, the origin point and the end point will repeat, which often cause overburn and affect the smoothness.
If this distance option is enabled, the system will automatically disable the arc voltage and the height control in
such a distance from the endpoint , in mm.
12.5. Control Parameters Setting
In the SETUP submenu, press [F5] key to enter control parameters setting window, as shown in Fig. 12.6
Flame/plasma option——
Take 0 for flame machining and 1 for plasma machining.
Move hole option——
0 stands for disabling the option and 1 for enabling the option.
Fig.12.5 Plasma Parameters Setting
SETUP
main menu
Parameters
display
zone
ESC
Parameter
setting
range
Remarks
zone
Fig. 12.6 Control parameters menu
SETUP
main menu
Paramete
rs display
zone
ESC
Parameter
setting range
Remarks
zone