E-15
E-14
English
AMP Device Mode
The
A
Device Mode button configures the CR902 to
control your Arcam amplifier. Pressing this button does
not affect the currently selected input on the amplifier.
P
Toggles power between standby and on
DISP
Cycles through the front panel display’s
brightness options
MENU
Displays the amplifier setup menu on the
front panel
Navigate menus
O
confirms a selection
@
Toggles the mute function of the amplifier
VOL-
VOL+
Decrease (
–
) and increase (
+
) amplifier
volume
SP1
Toggles Speaker 1 output
SP2
Toggles Speaker 2 output
BAL
Adjusts the balance between the left and
right audio channel
TUN Device Mode
The
T
Device Mode button configures the CR902 to
control the tuner functions of Arcam tuners.
P
Toggles power between standby and on
0
…
9
The numeric keys are used to store and
recall presets
DISP
Cycles through the front panel display’s
brightness options
INFO
Cycle through different information
display modes
)
Rewind iPod
(
Fast forward iPod
]
Preset down/Sirius category down/iPod
track back
[
Preset up/Sirius category up/iPod track
forward
#
Stop iPod
$
Play / pause iPod
&
Play / pause iPod
MENU
Displays the tuner setup menu on the front
panel
' ,
Preset up / down, iPod track back / forward
< >
Decrement / increment tuning frequency
O
Confirm a selection
FM MONO
Toggle FM mode between mono and stereo
reception
P/TUNE
Enter/Exit Preset recall mode
STORE
Enter/Exit Preset store mode
BAND
Cycles through available tuner bands
CD Device Mode
The
c
Device Mode button configures the CR902 to
control the CD functions of Arcam CD players.
P
Toggles power between standby and on
!
Open/close disc tray
0
…
9
The numeric keys allow direct access to
individual tracks on a disc. To select a track
press the corresponding keypad button.
For tracks greater than 9, enter the digits
in sequence. For example, to play track 15,
press
1
, then press
5
.
DISP
Cycles through the front panel display’s
brightness options
MODE
Changes the available display modes on the
CD player
)
Fast rewind
(
Fast forward
]
Skip back to the start of the current/
previous track
[
Skip forwards to the start of the next track
#
Stop playback
$
Play
&
Toggles pause of playback
MENU
Enter a track in a programmed track list
Navigates track listings if supported by the
player
O
selects the currently highlighted track if
supported by the player
SHUFF
Toggles random (‘shuffle’) play on and off
RPT
Repeat playback of the disc or pre-
programmed selection of tracks. To repeat
a particular track, select that track and press
RPT
twice. To cancel, press
RPT
a third time.
SACD
Toggles between selecting the HD and CD
layer of SACD disc
BD Device Mode
The
B
Device Mode button configures the CR902 to
control the BD functions of Arcam BD players.
P
Toggles power between standby and on
!
Open/close disc tray
0
…
9
The numeric keys allow direct access to
individual tracks on a disc. To select a track
press the corresponding keypad button.
For tracks greater than 9, enter the digits
in sequence. For example, to play track 15,
press
1
, then press
5
.
DISP
Cycles through the front panel display’s
brightness options
MODE
Changes the available display modes on the
BD player
)
Fast rewind
(
Fast forward
]
Skip back to the start of the current/
previous track
[
Skip forwards to the start of the next track
#
Stop playback
$
Play
&
Toggles pause of playback
AUDIO
Changes audio decode format (Dolby
Digital, DTS, etc.).
MENU
Activates BD player menu.
Navigates track listings if supported by the
player
O
selects the currently highlighted track if
supported by the player
.
Returns navigation to the top level of the
menu (‘Home’).
RTN
When navigating a menu, press this key to
return to the previous screen or selection
SHUFF
Toggles random (‘shuffle’) play on and off
RPT
Repeat playback of the disc or pre-
programmed selection of tracks. To repeat
a particular track, select that track and press
RPT
twice. To cancel, press
RPT
a third time.
SACD
Toggles between selecting the HD and CD
layer of SACD disc
loudspeakers
Normal single wiring
For single wiring, we recommend that you use the
SPEAKER 1
set of terminals on your amplifier. If each
speaker has more than one pair of connecting terminals,
use the terminals labelled
LF
or ‘Low Frequency’.
Connect the red positive terminal of the right speaker
connection on the amplifier (labelled
R+
) to the positive
terminal of your right speaker. Similarly, connect the
black negative terminal of the right speaker connection
on the amplifier (labelled
R-
) to the negative terminal
of your speaker. Repeat the process for the left speaker,
using the terminals labelled
L+
and
L-
on the amplifier.
WARNING: If your speakers support bi-wiring, there will be a
strip of conductive metal connecting the low-frequency (
LF
)
terminals to the high-frequency (
HF
) terminals; this MUST NOT
BE REMOVED in a single-wired system.
Notes on making speaker connections
<
Do not make any connections to any amplifier while it is switched on. We recommend that your
amplifier is completely disconnected from the mains supply before starting.
<
Before switching your amplifier(s) on for the first time after connecting to speakers, please check all
connections thoroughly. Ensure that bare wires or cables are not touching each other or the amplifier’s
chassis (which could cause short circuits), and that you have connected positive (+) to positive and
negative (–) to negative. Be sure to check the wiring for both the amplifier and the speaker.
<
After making connections: switch the amplifier(s) on, select a source signal, then gradually increase the
volume to the required listening level.
<
If you are unsure as to how your system should be connected, or need advice on bi-amping, please
contact your Arcam dealer who will be happy to help you.
Connecting
loudspeakers
There are many different ways of connecting your
loudpeakers to your A49 or P49/P349 and the following
section describes how to connect and configure the
loud speakers and amplifier for the most common
configurations.
PHONO
GROUND
ONLY
PHONO
(MM)
CD
TUNER
SAT
BD
PVR
AV
RECORD
OUT
PRE
OUT
R
4–16 OHMS. CLASS 2 WIRING
SPEAKER 1
SPEAKER 2
L
4–16 OHMS. CLASS 2 WIRING
SPEAKER 2
SPEAKER 1
AUX R
AUX L
PRE OUT R
PRE OUT L
TRIGGER OUT
6V 1A 12V 1.5A
ACCESSORY
POWER
110-120V/220-240V ~ 50-60 Hz
350W MAX
POWER INLET
SUPPLY
VOLTAGE
SWITCH POSITIONS
115 = 110 - 120V~
230 = 220 - 240V~
LF
HF
LF
HF
A49
An A49 connected to speakers using single wiring.
R
L
Bi-wiring
Bi-wiring is performed in the same way as single wiring
except that, a pair of cables are used to connect the
amplifier to each speaker.
Follow the instructions given for single wiring; then
perform the same actions, this time connecting the
SPEAKER 2
set of terminals on your amplifier to the
terminals labelled HF or ‘High Frequency’ for each
speaker.
WARNING: Speakers that support bi-wiring have a strip of
metal that connects the low frequency (
LF
) terminals to the
high frequency (
HF
) terminals. This MUST BE REMOVED in a
bi-wired system.
PHONO
GROUND
ONLY
PHONO
(MM)
CD
TUNER
SAT
BD
PVR
AV
RECORD
OUT
PRE
OUT
R
4–16 OHMS. CLASS 2 WIRING
SPEAKER 1
SPEAKER 2
L
4–16 OHMS. CLASS 2 WIRING
SPEAKER 2
SPEAKER 1
AUX R
AUX L
PRE OUT R
PRE OUT L
TRIGGER OUT
6V 1A 12V 1.5A
ACCESSORY
POWER
110-120V/220-240V ~ 50-60 Hz
350W MAX
POWER INLET
SUPPLY
VOLTAGE
SWITCH POSITIONS
115 = 110 - 120V~
230 = 220 - 240V~
LF
HF
LF
HF
A49
An A49 connected to two sets of speakers using bi-wiring.
R
L
Remove
metal strip