background image

EmETXe-i250C

COM Express Type 6 CPU Module

User’s Manual

Version 1.1

2016.09

Содержание EmETXe-i250C

Страница 1: ...EmETXe i250C COM Express Type 6 CPU Module User s Manual Version 1 1 2016 09...

Страница 2: ...This page is intentionally left blank...

Страница 3: ...Dimensions 8 Chapter 2 Installation 9 2 1 What is COM Express 10 2 2 Block Diagram 12 2 3 Connectors 13 2 4 COM Express AB Connector bottom side 14 2 5 COM Express CD Connector bottom side 15 2 6 The...

Страница 4: ...Boot Settings 40 3 5 Security 41 3 6 Save Exit 43 3 7 AMI BIOS Checkpoints 44 3 7 1 Checkpoint Ranges 44 3 7 2 Standard Checkpoints 45 Appendix 53 Appendix A I O Port Address Map 54 Appendix B Interru...

Страница 5: ...1 Introduction 1 Chapter 1 Introduction Chapter 1 Introduction...

Страница 6: ...t is in compliance with the directives of the Union European EU A Certificate of Compliance is available by contacting Technical Support This product has passed the CE test for environmental specifica...

Страница 7: ...cal and Electronic Equipment RoHS Directive 2002 95 EC The above mentioned directive was published on 2 13 2003 The main pur pose of the directive is to prohibit the use of lead mercury cadmium hexava...

Страница 8: ...r source when you want to work on the inside 2 Hold the board by the edges and try not to touch the IC chips leads or cir cuitry 3 Use a grounded wrist strap when handling computer components 4 Place...

Страница 9: ...e use misuse of or inability to use this product Vendor will not be liable for any claim made by any other related party Vendors disclaim all other warranties either expressed or implied including but...

Страница 10: ...ure that the following materials have been shipped 1 x COM Express CPU Module 1 x Driver CD 1 x Quick Installation Guide EmETXe i250C D25 Intel Atom D2550 1 86GHz COM Express CPU module HS 250C F2 Hea...

Страница 11: ...ort Analog RGB LCD SIngle Channel 24 bit LVDS 2 x DDI ports Ethernet controller 1 x Intel 82583V Gigabit Ethernet controller BIOS AMI UEFI BIOS Storage 2 x Serial ATA ports w 300MB s HDD transfer rate...

Страница 12: ...8 Introduction 1 11 Board Dimensions Cedar View D NM10 SB Unit mm 45 35 76 00 4 00 45 85 95 00 95 00 87 00 4 00 2 70...

Страница 13: ...9 Installation 2 Chapter 2 Installation Chapter 2 Installation...

Страница 14: ...Row AB which is required provides pins for PCI Express SATA LVDS LCD channel LPC bus system and power management VGA LAN and power and ground interfaces Row CD which is optional provides SDVO and lega...

Страница 15: ...r rows of pins 440 pins EmETXe i250C is a Type 6 module Connector placement and most mounting holes have transparency between Form Factors Connector difference between Standard Type 6 and EmETXe i250C...

Страница 16: ...PI Bus 2 x PCIex1 SPI BIOS Fintek F75111 SMBus HD Audio Link GbE LAN1 PCIex1 Intel 82583V GbE controller 8 x USB ports SMBus LPC I F 8 bit Digital I O Intel Atom D2550 at 1 86GHz 1 x SO DIMM socket In...

Страница 17: ...13 Installation 2 3 Connectors Top side COM Express CD Connector COM Express AB Connector NM10 SB Cedar View D SO DIMM socket Bottom side COM Express AB Connector COM Express CD Connector...

Страница 18: ...CC_RTC A47 EXCD0_PERST A48 EXCD0_CPPE A49 LPC_SERIRQ A50 GND A51 PCIE_TX5 A52 PCIE_TX5 A53 GPI0 A54 PCIE_TX4 A55 B56 PCIE_RX4 B57 GND B58 PCIE_RX3 B59 PCIE_RX3 B60 GND B61 PCIE_RX2 B62 PCIE_RX2 B63 GP...

Страница 19: ...RSVD C35 N C C36 N C C37 N C C38 N C C39 N C C40 GND FIXED C41 N C C42 N C C43 N C C44 RSVD C45 N C C46 N C C47 RSVD C48 N C C49 N C C50 GND FIXED C51 N C C52 N C C53 TYPE0 C54 N C C55 D56 N C D57 TY...

Страница 20: ...16 Installation 2 6 The Installation Paths of CD Driver Windows 7 Driver Path Chipset EmETXe i250x CHIPSET WIN7 LAN EmETXe i250x ETHERNET VGA EmETXe i250x GRAPHICS Audio EmETXe i250x AUDIO...

Страница 21: ...17 BIOS 3 Chapter 3 BIOS Chapter 3 BIOS...

Страница 22: ...ow keys to highlight a particular configuration screen from the top menu bar or use the down arrow key to access and configure the information below NOTE In order to increase system stability and perf...

Страница 23: ...he Day automatically changes when you set the date The date format is Day Sun to Sat Month 1 to 12 Date 1 to 31 Year 1999 to 2099 3 2 Advanced Settings Launch PXE OpROM Enable or disable the boot opti...

Страница 24: ...e specifies what PCI Option ROM to launch PCI Latency Timer Value to be programmed into PCI Latency Timer Register VGA Palette Snnop Enables or Disabled VGA Palette Registers Snooping PERR Generation...

Страница 25: ...nation OS S4 Sleep State This option may be not effective with some OS ACPI Sleep State Select the highest ACPI sleep state the system will enter when the SUSPEND button is pressed The choice Suspend...

Страница 26: ...Linux OS optimized for Hyper threading Technology and disabled for other OS OS not optimized for Hyper threading Technology When disabled only one thread per enabled core is enabled Limit CPUID Maxim...

Страница 27: ...Xe i65M2 RAID Enable or disable SATA devices It allows you to select the operation mode for SATA controller IDE Set the Serial ATA drives as Parallel ATA storage devices AHCI Allow the Serial ATA devi...

Страница 28: ...o enable support for operating systems without an EHCI hand off feature Do not disable the BIOS EHCI Hand Off option if you are running a Windows operating system with USB device The choice Enabled De...

Страница 29: ...y Maximum time the device will take before it properly reports itself to the host controller Auto uses default value for a Root port it is 100ms for a Hub port the delay is taken from hub descriptor T...

Страница 30: ...set up or change the Super IO configuration for parallel ports and serial ports Power On After Power Failure Specify what state to go to when power is re applied after a power failure Power On by mod...

Страница 31: ...rial port The choice Enabled Disabled Change Settings Use the Change Settings option to change the serial port s IO port address and interrupt address The choice Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6...

Страница 32: ...e Auto IO 378h IRQ 5 IO 378h IRO 5 6 7 10 11 12 IO 378h IRQ 5 6 7 10 11 12 IO 278h IRQ 5 6 7 10 11 12 IO 38Ch IRQ 5 6 7 10 11 12 Device Mode The choice Standard Parallel Port Mode EPP Mode ECP Mode EP...

Страница 33: ...29 BIOS 3 2 7 F71869 H W Monitor PC Health Status The hardware monitor menu shows the operating temperature and system voltages of CPU module...

Страница 34: ...30 BIOS 3 3 Chipset This section allows you to configure and improve your system also set up some system features according to your preference...

Страница 35: ...31 BIOS Memory Frequency and Timing 3 3 1 Host Bridge Parameters...

Страница 36: ...32 BIOS Enable or disable MRC fast boot MRC Fast Boot Enable or disable Dyn SR Dyn SR...

Страница 37: ...ct the LCD panel scaling option used by the Internal Graphics Device Auto Off Force Scaling Panel Scaling Auto disable IGD upon external GFX detected Auto Disable IGD Select the Video Device which wil...

Страница 38: ...Disabled and Level 1 2 3 4 5 BIA ISD clock selection ISD Clock Source Configure fixed Graphics memory size Fixed Graphics Memory Size Backlight control configuration Backlight Control Support The cho...

Страница 39: ...h Priority port Enables or Disables PCI Exp High Priority port PCIE Card0 1 Enables or Disables PCIE Card0 1 High Precision TImer Enables or Disables High Precision Timer SPI ROM Control Enables or Di...

Страница 40: ...ntroller USB 2 0 EHCI Support Enable or Disable USB 2 0 EHCI LAN controller Enable or Disable OnChip NIC Controller SMBus controller Enable or Disable SMBus controller SIRQ Logic Enable or Disable SIR...

Страница 41: ...bled AH Audio Azalia will be enabled if present disabled otherwise TPT Deviced Enable Disable Intel R IO Controller Hub TPT devices Azalia PME Enable Enable or Disable Power Management capability of A...

Страница 42: ...oot Port 0 5 Control the PCI Express Root Port PCI Express Root Port 0 5 ASPM Support Set the ASPM Level to Disabled L0s L1 L0sL1 Auto Force L0 Force all links to L0 State AUTO BIOS auto configuration...

Страница 43: ...PCI Express PME SCI PME SCI Enable or disable Root PCI Express System Error on Non Fatal Error SENFE Enable or disable PCI Express Hot Plug Hot Plug Enable or disable Root PCI Express System Error on...

Страница 44: ...s setting determines whether the Num Lock key should be activated at boot up Fast Boot Enables or disables boot with initialization of a minimal set of devices requered to launch active boot optoin Ha...

Страница 45: ...firm the password Type the password again and press Enter You may also press ESC to abort the selection and not enter a password To disable a password just press Enter when you are prompted to enter t...

Страница 46: ...your system is rebooted This would prevent unauthorized use of your computer You can determine when the password is required within the BIOS Features Setup Menu and its Security option If the Security...

Страница 47: ...on this item and it asks for confirmation prior to executing this command Save Changes and Reset Pressing Enter on this item and it asks for confirmation Save configuration changes and exit setup Pres...

Страница 48: ...xecution up to and including memory detection 0x30 0x4F PEI execution after memory detection 0x50 0x5F PEI errors 0x60 0x8F DXE execution up to BDS 0x90 0xCF BDS execution 0xD0 0xDF DXE errors 0xE0 0x...

Страница 49: ...ding 0x05 OEM initialization before microcode loading 0x06 Microcode loading 0x07 AP initialization after microcode loading 0x08 North Bridge initialization after microcode loading 0x09 South Bridge i...

Страница 50: ...nitialization North Bridge module specific 0x19 Pre memory South Bridge initialization is started 0x1A Pre memory South Bridge initialization South Bridge module specific 0x1B Pre memory South Bridge...

Страница 51: ...Memory North Bridge initialization North Bridge module specific 0x3B Post Memory South Bridge initialization is started 0x3C Post Memory South Bridge initialization South Bridge module specific 0x3D P...

Страница 52: ...0xE2 Video repost 0xE3 OS S3 wake vector call 0xE4 0xE7 Reserved for future AMI progress codes S3 Resume Error Codes 0xE8 S3 Resume Failed 0xE9 S3 Resume PPI not Found 0xEA S3 Resume Boot Script Error...

Страница 53: ...x68 PCI host bridge initialization 0x69 North Bridge DXE initialization is started 0x6A North Bridge DXE SMM initialization is started 0x6B North Bridge DXE initialization North Bridge module specific...

Страница 54: ...M DXE initialization codes 0x90 Boot Device Selection BDS phase is started 0x91 Driver connecting is started 0x92 PCI Bus initialization is started 0x93 PCI Bus Hot Plug Controller Initialization 0x94...

Страница 55: ...0xB1 Runtime Set Virtual Address MAP End 0xB2 Legacy Option ROM Initialization 0xB3 System Reset 0xB4 USB hot plug 0xB5 PCI bus hot plug 0xB6 Clean up of NVRAM 0xB7 Configuration Reset reset of NVRAM...

Страница 56: ...s entering S2 sleep state 0x03 System is entering S3 sleep state 0x04 System is entering S4 sleep state 0x05 System is entering S5 sleep state 0x10 System is waking up from the S1 sleep state 0x20 Sys...

Страница 57: ...53 Appendix Appendix Appendix...

Страница 58: ...er 0x000000C0 0x000000DF Direct memory access controller 0x00000020 0x00000021 Programmable interrupt controller 0x00000024 0x00000025 Programmable interrupt controller 0x00000028 0x00000029 Programma...

Страница 59: ...ces 0x00000080 0x00000080 Motherboard resources 0x00000092 0x00000092 Motherboard resources 0x000000B2 0x000000B3 Motherboard resources 0x00000680 0x0000069F Motherboard resources 0x00001000 0x0000100...

Страница 60: ...0FF Numeric data processor 0x0000F130 0x0000F137 Standard Dual Channel PCI IDE Controller 0x0000F120 0x0000F123 Standard Dual Channel PCI IDE Controller 0x0000F110 0x0000F117 Standard Dual Channel PCI...

Страница 61: ...PCI standard PCI to PCI bridge IRQ 11 Video Controller VGA Compatible IRQ 11 PCI PCI Simple Communications Controller IRQ 5 Ethernet Controller IRQ 5 SM Bus Controller IRQ 22 Microsoft UAA Bus Driver...

Страница 62: ...ns Controller 0xF7C00000 0xF7C1FFFF Ethernet Ethernet Controller 0xF7C28000 0xF7C28FFF Ethernet Ethernet Controller 0xF7C27000 0xF7C273FF Standard Enhanced PCI to USB Host Con troller 0xF7C20000 0xF7C...

Страница 63: ...FFFFF Motherboard resources 0xFED20000 0xFED3FFFF Motherboard resources 0xFED90000 0xFED93FFF Motherboard resources 0xFED45000 0xFED8FFFF Motherboard resources 0xFEE00000 0xFEEFFFFF Motherboard resour...

Страница 64: ...11R s Add 6eh int i j printf Fintek F75111 DIO LED TEST Program Ver 0 1 n printf Warning This tools is test only n Index 10 GPIO1x Output pin control SMB_Byte_WRITE SMB_PORT_AD SMB_DEVICE_ADD 0x10 0xf...

Страница 65: ...ear delay 10 outportb SMPORT 04 DeviceID 1 clear outportb SMPORT 03 REG_INDEX clear outportb SMPORT 02 0x48 read_byte delay 10 printf 02x inportb SMPORT 05 SMB_Byte_WRITE int SMPORT int DeviceID int R...

Отзывы: