Installation
User Manual Chemical centrifugal pumps with mechanical seal V080716
23
5.4
Check the rotation of the product
5.4.1
Check
1. Set the product to ‘on’ for maximum 2 s
and see if the rotation of the fan is
correct as indicated on the product.
See also §
.
2. After maximum 2 s, set the product to
‘off’.
5.4.2
If the rotation of the product is not correct
1. Open the electrical box (A).
2. Change the electrical connection. It is
enough to change two phases.
3. Close the electrical box.
4. Check the rotation of the product again.
CAUTION
When the product turns in the wrong direction, this may cause
damage to the product.
A