11.2 Standard Command Set
99
11.2.9
Date and Time Commands
Set Receiver Time
Command:
yyyy:MM:dd:hh:mmTS
Sets the receiver to UTC time
only available on initial power up and not locked to the GNSS
.
Format: yyyy = year
MM = month
dd
= day
hh
= hour
mm = minute
Response:
<
CR
><
LF
>
Return Local Date, Return UTC Date
Command:
DL, DU
Returns the current date in local time or UTC.
Format: DL = local time
DU = UTC
Response: ddmmmyyyy
<
CR
><
LF
>
Where: dd
= day of month
mmm = month, three character abbreviation
yyyy
= year
Return Local Time, Return UTC Time
Command:
TL, TU
Returns the current time in local time or UTC.
Format: TL = local time
TU = UTC
Response: ddd:hh:mm:ss
<
CR
><
LF
>
Where: ddd = Julian day of year
hh
= hour
mm = minute
ss
= second
11.2.10
Programmable Pulse Output Commands
Pulse Width, Seconds-Per-Pulse
Command:
nnn.nnPW
Configures the pulse width for the Programmable Pulse output.
Format:
nnn.nn = 0.01 to 600 seconds in 10-millisecond increments
Response:
<
CR
><
LF
>
For values greater than 1, use a decimal point and enter trailing zeros as applicable.
Examples: 1 = 0.01 second
10 = 0.10 second
1.00 = 1 second
100 = 1 second
Содержание 1200B
Страница 4: ...iv ...
Страница 135: ...A 3 Physical Dimensions 117 Figure A 2 Suggested Mounting of the GNSS Surge Arrester ...
Страница 143: ...B 7 Four Fiber Optic Outputs 125 Figure B 4 Jumper Locations ...
Страница 145: ...B 8 8 Channel High Drive IRIG B Amplifier 127 Figure B 5 8 High Drive Outputs Jumper Locations ...
Страница 161: ...B 10 Four Additional Outputs and Dry Contacts 25 50 Vdc 143 Figure B 7 Option Connector Signal Locations ...
Страница 212: ...Appendix E Statement of Compliance The following page is a statement of compliance that includes Model 1201B and 1201C ...