Control panel - NOX CPA
Quickguide
Version Change
Author
1.0
First version
Jasper Johansen
1.1
LED and
cardreader added Jasper Johansen
Страница 1: ...Control panel NOX CPA Quickguide Version Change Author 1 0 First version Jasper Johansen 1 1 LED and cardreader added Jasper Johansen ...
Страница 2: ...Table of Contents Keys 3 LED Status 4 Start Screen 5 Login 6 Main Menu 7 Alarm Menu 8 Warnings Menu 9 Area Menu 10 Logs Menu 15 User Menu 16 Time Profile Menu 17 Service Menu 18 ...
Страница 3: ... is shown on the display just above each key Scroll keys The 2 scroll keys up and down are used to navigate in the menu structure Numeric keys The numbers on the numeric keys are used for entering codes and time settings Clear key The clear key is used to delete mistyped numbers for example during code entry Enter key The enter key is used to authenticate entered numbers for example after code ent...
Страница 4: ...quiped with four programmable status LED s As default the for LED s will give these informations LED Color Description Green Normal operation Green All areas are not armed turns off when all areas are armed Red Active alarm Gul Technical problem login for description ...
Страница 5: ...information for example the phone number to the associated control center In case of alarm the internal buzzer in the control panel will sound Press Silent to stop the buzzer this only stops the sound not the alarm If your system is in service mode the service level will be shown on the main screen ...
Страница 6: ... code to the number higher 1 For example Normal code Duress code 1000 1001 4567 4568 456789 456780 NOTE If 5 invalid user codes are entered within 3 minutes adjustable the control panel locks itself and will not accept further codes invalid or valid for 3 minutes Additional error codes will cause the system to block for a longer time To unlock the control panel it s necessary to make an alarm or w...
Страница 7: ...ystem Warnings Shows any problem with your system fx AC power loss Also shows any disabled detectors Areas Shows the status of the areas of your system Let s you arm and disarm areas Logs Informs you about any status change of the system User Let s you manage your codes Time profiles Let s you manage the different access times for areas and codes Service Functions for service personnel normally no...
Страница 8: ...op row of the display It also shows time date room area and which de tector triggered the alarm Possible problems acknowledging alarms A User has no right to acknowledge an alarm of a specific type Solution use another user code with more rights B The detector is still active and the area is still armed Solution disarm the area or try to make the detector not active anymore The acknowledgement dis...
Страница 9: ...g AC loss up to 30 minutes You are not able to acknowledge a warning the warning will be automatically acknowledged once the problem is resolved e g by restoring AC A warning is also generated as long there is a deactivated detector The warning will be removed as soon as the detector is reactivated by disarming the area ...
Страница 10: ...of 8 areas is shown To switch to a different area use the scroll keys on the panel or enter the number of the requested area and press E enter Area option menu Press select on the area to enter the area options menu Generally you have the following options available Arm disarm depending on current area state Test normally only available if area is disarmed Deactivate normally only available if are...
Страница 11: ...possible to arm an area it will be shown on the control panel Error Description Solution Active detectors There are active detectors in that area Try to get all detectors inactive e g close the doors and windows If this is not possible deactivate those detectors Active alarms There is one ore more active alarms in the area Acknowledge the alarms In block time The area is in block time Wait until a...
Страница 12: ...d from armed to disarmed all previously deactivated detectors in that area are reactivated This is necessary to prevent one from forgetting any deactivated detectors Any deactivated detectors will be shown in the warning menu There you can view when and by whom the detectors have been deactivated If there are more detectors to deactivate they will be shown if you press back If there are no more yo...
Страница 13: ... using the scroll keys or by entering the detector number and pressing E enter You can also see the current live status of the detector if input is closed open or sabotaged Deactivate detectors in advance Select the area in which you want to deactivate the detector In the option menu select the option deactivate You will see a list of detectors you are allowed to deactivate Select the detector you...
Страница 14: ... by pushing the E button The new end time can immediately be seen in the area status in the line Access until hh mm Access time If the area is associated with an access time users with sufficient rights have the option of changing the day s access time closing time This will cause no change in general only in regards to today s closing time and thus the time of the automatic arming or lockout ...
Страница 15: ...personnel All logs all logs together The logging screen shows one log entry at the time On the top row of the display the total number of log entries is displayed As you cycle through the list the first number will always show your current position within the list All logs are shown from the most recent log entry to the oldest Alarm log User log Alarm log log entry no 3 out of 25 User log log entr...
Страница 16: ...he functions in this menu are restricted to users with complete access rights e g the owner of the system User creation and editing is easier quicker and more manageable through the NOX PC operating software Read more about creating users both via the control panel and the PC operating soft ware in the NOX user manual ...
Страница 17: ...ne new special days and delete existing special days The creation and editing of time profiles is easier quicker and more manageable through the NOX PC operating software Read more about creating time profiles both via the control panel and the PC operat ing software in the NOX user manual ...
Страница 18: ...evel 3 Like Level 2 but turns off ALL alarm transmissions This is normally used for system update and is only available for specific service users If the system is in level 1 2 or 3 the state is displayed on all control panels of the system The service menu divides into two sub menus service mode and date time Users may often have access to date time but access to service mode is restrict ed If se...
Страница 19: ...ll detectors and outputs Read more about it in the NOX user manual Set date and time Unless a DCF radio clock receiver device is installed in the system the actual time and date can be adjusted This is done by accessing the service menu and then select ing date time ...
Страница 20: ...old in the Nordic region by the distributor ARAS Security A S Please contact us Sjælland Jylland Tlf 45 70 27 40 90 Mose Alle 10B Vardevej 1 info aras dk 2610 Rødovre 9220 Aalborg www aras dk www noxsystems com ...