VP5000-DC/DC60, VP5000-DC/DC200-HL
Product description
Last edited 2019-02-08
by Sonja Scheunert
Filename
VP5000_DCDC60_200-HL_installation_manual_v1-4en.docx
32 / 173
VECTOPOWER
VP5000-DC/DC60
VECTOPOWER
VP5000-DC/DC200-HL
This information is found on the rating plate.
Table 15: General data and environmental data
3.3.8
Data for cooling
VECTOPOWER
VP5000-DC/DC60
VECTOPOWER
VP5000-DC/DC200-HL
Cooling temperature
-25 °C to +65 °C / -13 °F to 149 °F
Maximum cooling
temperature without
derating
35 °C / 95°F
Maximum cooling
temperature with derating
65°C / 149°F
Coolant flow rate
at full load 30 l/min / 8 gpm
at 35
°C / 95 °F
Coolant
Water:glycol 50:50 (70:30 .... 40:60)
The mixing ratio must ensure frost protection down to -25 °C.
Water of drinking water quality according to the drinking water directive
98/83/EC
Particle size < 300 µm
pH value 6 - 8
Maximum pressure in the
cooling system
2 bar
Minimum pressure in the
cooling system
0.5 bar
Table 16: Data for cooling
See chapter 3.10 Product description, Characteristic curves for derating