8 Care for your Ecoboiler stove 

The following items should be checked on your stove at regular intervals to help ensure that the 

safe and efficient use of your stove continues for many years to come. This should only be done 

when the stove is unlit and cold. 

 

8.1 Adjusting the door hinges 

Once the appliance has been under fire for a period of time the fire door may appear to have 

moved out of alignment with relation to the door aperture or catch. This is quite normal and due to 

the settling of the casting. Doors attached with two hinges fixed to the body with screws can be re

-

aligned as follows: 

1. 

When the appliance is cold, open the fire door so that it is at right angles to the front of the 

stove and then lift the fire door up off of its hinges. 

2. 

Gently tap the hinge pins to compensate for the misalignment and then re-fit the door and 

check to ensure it now sits square to the body; if not repeat the previous step. 

 

If the fire door needs to be raised, please follow the instructions below: 

1. 

When the appliance is cold, open the fire door so that it is at right angles to the front of the 

stove and lift the fire door up of the hinges. 

2. 

Drop one washer on the top and bottom hinge pins. Fit the door and check. Repeat again if 

necessary. 

 

8.2 Fire door seal 

The rope seal around the edges of the main fire door should also be checked. Look for signs of 

fraying, peeling away or the ends not meeting. If the rope is unable to create a good seal with the 

stove body it should be replaced.  A poor seal will decrease your ability to control the burn rate 

and its efficiency whilst leading to an increase in heat lost through the flue. 

 

8.3 Cracked glass 

It is not recommended to operate the stove with cracked glass; this can lead to over firing due to 

air leaking into the firebox and it may fail completely leading to personal injury or a fire. 

 

You 

should discontinue use of your stove until it has been repaired. You can source replacement 

glass kits from 

www.aradastovesandspares.com

Содержание Ecoboiler

Страница 1: ...PLEASE RETAIN THIS GUIDE FOR FUTURE REFERENCE BK 560 SPECIFIC Rev 10 ISSUE DATE 01 4 2016 BS EN 13240 2001 A2 2004 BS EN 13229 2001 A1 2003 A 2004 CE Ecoboiler Stove User Guide...

Страница 2: ...ime of heating satisfaction Should you have any questions about your stove which are not covered by this manual please contact the Arada retailer in your area call our technical support department on...

Страница 3: ...1 Refuelling on to a low fire bed 11 6 Further information for all stove owners 6 1 Reduced burning 11 6 2 Over firing 12 6 3 Chimney fires 12 6 4 Periods of non use 12 6 5 Ash removal 13 6 6 Multi f...

Страница 4: ...NOT be burned in this appliance The use of these fuels will invalidate the appliance guarantee Please ensure that air inlet vent grills to the dwelling are not obstructed or liable to be blocked Caut...

Страница 5: ...ained in order to determine the moisture content of your wood fuel Wet wood must not be used as this will greatly contribute to the creation of tar and creosote which may in extreme cases run down the...

Страница 6: ...nce Suitable provision for combustion and ventilation air depending upon Building Regulations have been undertaken by the installation fitter Consideration must be given for the need for extra ventila...

Страница 7: ...y Air The primary air is supplied through the thermostatically controlled air inlet beneath an access cover on left side of your stove This should have been calibrated when the stove was installed See...

Страница 8: ...assist whilst lighting the fre Once lit the Easy Boost inlet should be used for a temporary increase in boiler output when required It should be used for short periods only and will temporarily overri...

Страница 9: ...criss cross grid pattern on top of the grate The use of two or three fire lighters may assist in lighting the kindling 2 Fully open the airwash and Easy Boost air control and light the fire lighters...

Страница 10: ...od fuel see steps 1 2 and 3 of section Burning Wood with kindling and fire lighters 3 Once flue draw has been established carefully load the stove with fuel and close the door 4 When the fire is well...

Страница 11: ...a new fuel charge excessive smoke emission can occur Refuelling must be carried out onto a sufficient quantity of glowing embers and ash that the new fuel charge will ignite in a reasonable period If...

Страница 12: ...ce to reduce the air supply to the stove Move items of furniture and combustibles away from the surrounding area of the stove to reduce the risk of fire and allow access for the fire service Ensure ac...

Страница 13: ...al container Even if ash appears cold red hot embers may be concealed and could easily start a fire or cause injury 6 6 Multi fuel grate except Ecoboiler Wood The grate in your Ecoboiler stove compris...

Страница 14: ...It is then these objects such as the chimney breast hearth etc which heat the surrounding air in the room 7 2 Hot Water Your stove also has a boiler jacket integrated into the rear of the stove This...

Страница 15: ...w sits square to the body if not repeat the previous step If the fire door needs to be raised please follow the instructions below 1 When the appliance is cold open the fire door so that it is at righ...

Страница 16: ...your Arada stove We appreciate that we have given you a lot of information to read but we hope it has been clear and helpful and that you are now able to enjoy the full benefits of your stove However...

Страница 17: ...a red oxide colouring will demonstrate the over heating of internal parts body paint which has turned dusty white is also indicative of such use The following guarantee periods shall apply in respect...

Страница 18: ...ere flue draw readings have not been made to confirm a suitability of the flue The manufacturer s decision as to whether this condition has been satisfied shall be final 7 The guarantee does not cover...

Страница 19: ...ifications have been made to the stove which have been carried out by anyone other than Arada or its authorised representatives or approved dealers 14 All guarantee periods commence on the date of pur...

Страница 20: ...Date of issue 19 7 2016 BK560 Rev 10 All Arada Stoves are manufactured in the UK Arada Ltd The Fireworks Weycroft Avenue Axminster Devon EX13 5HU United Kingdom www aradastoves com T 44 0 1297 632050...

Отзывы: