4.3.7
Low or No Power Output (RF Test) (Schematic Diagram Nos.
10044770 and 10039874)
NOTE: The DC Tests specified in Section 4.3.8 should be completed before conducting the RF tests specified
in the following sections.
1.
The Model 350A400’s typical gain response at -20 dBm input and 0 dBm input is shown in Figure 4-1
and Figure 4-2. The actual gain may vary considerably from that shown in Figure 4-1 but should
be ≥
55.5 dBm at 0dBm input.
Figure 4-1. Typical Response at -20dBm Input
Figure 4-2. Typical Response at 0 dBm Input