Model 5000A225C
34
Rev A
2.8.6.16
Reverse Power Query
This command queries the internally detected reverse power (values are corrected and linearized).
Query:
RPOW?
Response Format:
RPOW=<power><LF>
<power>:
The detected reverse power (0-99999) in Watts (value is always five
characters, padded with spaces).
Example:
To query the reverse power, send the following command:
RPOW?<LF>
Response:
RPOW=<space><space><space><space>4<LF>
(4 Watts of forward power)
2.8.6.17
Operating Hours (RF ON) Query
This command queries the total hours spent with the RF enabled.
Query:
OH?
Response Format:
OH=<hours><LF>
<hours>:
The total hours with RF Enabled (0 to 100000), padded with spaces to always
be 6 digits wide.
Example:
To query the RF On operating hours, send the following command:
OH?<LF>
Response:
OH=<space><space><space><space>37<LF>
(The system has spent 37 Hours in an RF On state)
2.8.6.18
Operating Hours (Power ON) Query
This command queries hours spent in Power ON.
Query:
OHP?
Response Format:
OHP=x<LF>
<hours>:
The total hours with Power On (0 to 100000), padded with spaces to always be
6 digits wide.
Example:
To query the Power On operating hours, send the following command:
OHP?<LF>
Response:
OHP=<space><space><space>428<LF>
(The system has spent 428 Hours in a Power On state)
2.8.6.19
Faults Query
This command queries information about a currently active fault.
Query:
FSTA?
Response Format:
FSTA=<space><status><LF>
<status>:
A hexadecimal number (0000 to FFFF), padded with zeros to always be 4
characters wide.
Example:
To query the fault status, send the following command:
FSTA?<LF>
Response:
FSTA=<space>0003<LF>
(Interlock Fault)