2.8.6.14.1
Hex Character to Binary Bits Conversion Table
Below is a table that can be used as a reference when deciphering the response from the STATE query. The
binary bits of each of the four ASCII characters from the response can be located here.
Hex character to Binary Bits
ASCII
Char
Equivalent Binary Bits
Position 3 Position 2 Position 1 Position 0
1
0
0
0
1
2
0
0
1
0
3
0
0
1
1
4
0
1
0
0
5
0
1
0
1
6
0
1
1
0
7
0
1
1
1
8
1
0
0
0
9
1
0
0
1
A
1
0
1
0
B
1
0
1
1
C
1
1
0
0
D
1
1
0
1
E
1
1
1
0
F
1
1
1
1
2.8.6.15
Forward Power Query
This command queries the internally detected forward power (values are corrected and linearized).
Query:
FPOW?
Response Format:
FPOW=<power><LF>
<power>:
The detected forward power (0-99999) in Watts (value is always five
characters, padded with spaces).
Example:
To query the forward power, send the following command:
FPOW?<LF>
Response:
FPOW=<space><space><space>54<LF>
(54 Watts of forward power)