Model 5000A225C
Rev A
23
A#
Control
Line
Fault Details
RF
Inhibit?
= Yes
Drop to
RF OFF?
= Yes
Hex
Dec
Fault Text
(<15 Characters)
Description
A60
J5-30
0x020f
527
Amp A27
Amplifier Fault, Module A27
A60
J5-31
0x0210
528
Amp A28
Amplifier Fault, Module A28
A60
J5-32
0x0211
529
Amp A29
Amplifier Fault, Module A29
A61
J5-15
0x0400
1024
Therm A1
Thermal Fault, Module A1
A61
J5-16
0x0401
1025
Therm A2
Thermal Fault, Module A2
A61
J5-17
0x0402
1026
Therm A14
Thermal Fault, Module A14
A61
J5-18
0x0403
1027
Therm A15
Thermal Fault, Module A15
A61
J5-19
0x0404
1028
Therm A16
Thermal Fault, Module A16
A61
J5-20
0x0405
1029
Therm A17
Thermal Fault, Module A17
A61
J5-21
0x0406
1030
Therm A18
Thermal Fault, Module A18
A61
J5-22
0x0407
1031
Therm A19
Thermal Fault, Module A19
A61
J5-23
0x0408
1032
Therm A20
Thermal Fault, Module A20
A61
J5-24
0x0409
1033
Therm A21
Thermal Fault, Module A21
A61
J5-25
0x040a
1034
Therm A22
Thermal Fault, Module A22
A61
J5-26
0x040b
1035
Therm A23
Thermal Fault, Module A23
A61
J5-27
0x040c
1036
Therm A24
Thermal Fault, Module A24
A61
J5-28
0x040d
1037
Therm A25
Thermal Fault, Module A25
A61
J5-29
0x040e
1038
Therm A26
Thermal Fault, Module A26
A61
J5-30
0x040f
1039
Therm A27
Thermal Fault, Module A27
A61
J5-31
0x0410
1040
Therm A28
Thermal Fault, Module A28
A61
J5-32
0x0411
1041
Therm A29
Thermal Fault, Module A29
2.8 REMOTE OPERATION
This section describes remote operation of the amplifier using the provided General Purpose Interface Bus
(GPIB), RS-232 serial port, fiber-optic serial ports, Universal Serial Bus (USB), and Ethernet port. All ports
are always active, however only one port may be used at a time.
NOTE
:
Communicating through two or more ports at one time will cause data collisions and lost commands
or queries.
The Keylock switch on the control panel of the amplifier enables the remote-control functionality and must be
set to the REMOTE position before any commands will be accepted. All remote queries will work with the
Keylock switch in any position. When the Keylock switch is set to REMOTE, all front panel controls are
disabled unless otherwise specified.
The status of the amplifier should be checked remotely just prior to issuing a command as well as after a
command has been issued to ensure the command has been properly executed. When checking the status after
issuing a command, it is good practice to add a delay of 100ms or more to allow the control system time to
process the command.