2.5 AMPLIFIER OPERATION
2.5.1
Local Operation
1.
Connect the input signal to the unit’s RF INPUT connector. The input signal level should be 0dBm
maximum.
2.
Connect the load to the unit’s RF OUTPUT connector.
3.
Set the REMOTE/LOCAL switch to LOCAL.
4.
Check to see that the MAIN POWER switch on the unit’s rear panel is set to the 1 (on) position.
5.
Press the POWER switch.
6.
Place the unit in the Operate mode by pressing the RF On/Off touch screen button.
7.
Adjust the amplifier’s gain by rotating the ADJUST knob.
8.
In the event of a fault, press the RESET touch screen button; if the fault does not clear, refer to Section 4.3
Troubleshooting
of this manual.
2.6 LOCAL USER INTERFACE
This section describes the user interface used during local operation of the amplifier as it pertains to the control
system.
2.6.1
Menu Map
Below is a menu map for the amplifier. The screens depicted are only example screens. The actual values and
settings will be different on the actual amplifier depending on user settings and operating conditions.
Figure 2-3