![AR 10052381 Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/ar/10052381/10052381_operating-and-service-manual_2962299035.webp)
Model 125W1000A
Rev A
13
2.5.1
Power Off, RF Off
2.5.1.1
Description
AC power is applied, the Power button has not been pressed (LED status indicator not lit). The control system
is waiting for a user action or a remote command.
2.5.1.2
State Change Requirements
No change.
2.5.1.3
System Monitoring Requirements
No faults monitored in the power off state.
2.5.2
Power On, RF Off
2.5.2.1
Description
The Power button has been pressed or the remote command for ‘Power On’ has been sent.
2.5.2.2
State Change Requirements
Allow 2 seconds of delay before checking sending an FSTA or STATE remote query.
2.5.2.3
System Monitoring Requirements
The controls will actively monitor the thermal faults, Interlocks, and the driver power supply status.
2.5.3
Power On, RF On
2.5.3.1
Description
Amplifier RF output has been enabled.
2.5.3.2
State Change Requirements
Allow 2 seconds of delay before checking sending an FSTA or STATE remote query.
2.5.3.3
System Monitoring Requirements
In addition to the faults monitored in RF:OFF the amp faults and the final power supply status will be monitored.