Model 5000A225A
Rev B
27
2.4.2.6.8
Machine State
This query reads the RF gain, detector gain, ALC threshold, and ALC response time of the Model
5000A225A.
Syntax:
MSB?
Parameters:
None
Query only (always requires a ? character)
Response Format:
RF<space>GAIN=x,
DT<space>GAIN=x,
THRES=x,
RESP=y<LF>
Value(x): [x is always 3 characters in length, padded with leading spaces]
For RF Gain, Detector Gain, and ALC Threshold:
0
= Minimum
100
= Maximum
Value(y): [y is always 1 character in length]
For Response Time:
1
= Minimum
7
= Maximum
Table 2-5. Machine State Response Time
Response Time Setting
Time (mS)
1
5
2
10
3
30
4
100
5
1000
6
3000
7
3000
Example:
To get the machine state, send the following command:
MSB?<LF>
Response:
RF<space>GAIN=100,DT<space>GAIN=<space>50,THRES=<space>75,RESP=1
<LF>
(RF gain is 100%, Detector Gain is 50%, ALC Threshold is 75%, and ALC Response Time is set to 5mS)