![AR 10044005 Скачать руководство пользователя страница 38](http://html1.mh-extra.com/html/ar/10044005/10044005_operating-and-service-manual_2962284038.webp)
Model 5000A225A
24
Rev B
Table 2-4. Relationship between the Model 5000A225A Controls and Remote Communication
AC Power and
Circuit Breaker
Power
Keylock Switch
Remote
Communication
On
Off
On
Off
INHIBIT LOCAL REMOTE
Command
Query
√
X
X
√
√
√
√
√
√
√
√
√
√
√
√
√
X
√
√
√
√
X
√
√
√
√
X
√
√
√
√
X
√
X = No, √ = Yes
2.4.2.6.1
Power On/Off
This command controls the power on/off state of the Model 5000A225A.
Syntax:
POWER:x
Parameters:
State(x):
OFF
= power off
ON
= power on
Response Format: None (No query for this command)
Example:
To turn the power on, send the following command:
POWER:ON<LF>
To turn the power off, send the following command:
POWER:OFF<LF>
2.4.2.6.2
RF On/Off
This command controls the RF on/off state of the Model 5000A225A.
Syntax:
RF:x
Parameters:
State(x):
OFF
= power off
ON
= power on
Response Format: None (No query for this command)
Example:
To turn the RF on, send the following command:
RF:ON<LF>
To turn the RF off, send the following command:
RF:OFF<LF>