Model 250S1G6
Rev D
7
2.2.3
Main Power
The Main Power circuit breaker is located on the rear panel of the amplifier.
4
1
5
6
2
3
7
8
Figure 2-2. Rear Panel Features
Item
Title
Function
1
RF INPUT (rear connector versions)
Type N female connector
2
RF OUTPUT (rear connector versions)
Type N female connector
3
Safety Interlock
Type 13-pin sub-D
4
IEEE-488
Remote Interface
5
RS-232
Remote Interface
6
USB
Remote Interface
7
Fiber Optic Serial
Remote Interface
8
Ethernet
Remote Interface
2.2.4
RF ON/OFF
The RF ON/OFF touch screen button toggles the amplifier from a Standby to an Operate mode. The status of
the function is indicated on the display as RF ON or RF OFF. In the RF ON state, RF output is enabled
according to control settings and amplifier RF input. Main cooling fans will operate. In the RF OFF state,