OPERATING CONDITIONS & REQUIREMENTS
Page 4
OPERATING PRESSURE: min. 1,4 / max. 8,3 bar
this system is configured to perform optimally at an
operating pressure of 3 bar (±½ bar); in case of a lower or
higher operating pressure the performance may be
affected negatively!
check water pressure regularly.
take into account that night time water pressure may be
considerably higher than day time water pressure.
install a pressure reducer ahead of the water softener if
necessary.
OPERATING TEMPERATURE: min. 2 / max. 48 °C
do not install the water softener in an environment where
high ambient temperatures (e.g. unvented boiler house) or
freezing temperatures can occur.
the water softener cannot be exposed to outdoor
elements, such as direct sunlight or atmospheric
precipitation.
do not install the water softener too close to a water
heater; keep at least 3 m of piping between the outlet of
the water softener and the inlet of the water heater; water
heaters can sometimes transmit heat back down the cold
pipe into the control valve; always install a check valve at
the outlet of the water softener.
ELECTRICAL CONNECTION: 230V-50Hz
this water softener only works on 24VAC; it is equipped
with a 230/24V-50Hz transformer; always use it in
combination with the supplied transformer.
make sure to plug the transformer into a power outlet,
which is installed in a dry location, with the proper rating
and over-current protection.