background image

Ver.1.2 

Electric Cleaner for Industrial Application 

Operation Manual 

 

 

EVC-550 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pail can is not included, and sold separately. 

 

CONTENTS 

 

  8 

・・・・・

  Safety Instruction 

9       

・・・・・

  Specification 

10

 11 

・・・・・

  Part Names and Accessory 

12 

15 

・・・・・

  How to use 

16 

18  

・・・・・・

Maintenance & Inspection 

18 

19 

・・・・・

  Assurance & After-Service 

 

 

Содержание EVC-550

Страница 1: ...al Application Operation Manual EVC 550 Pail can is not included and sold separately CONTENTS 1 8 Safety Instruction 9 Specification 10 11 Part Names and Accessory 12 15 How to use 16 18 Maintenance Inspection 18 19 Assurance After Service ...

Страница 2: ...n in case of the contents with Caution mark depending on the situation be noted that it may cause serious incidents All the information contained herewith are quite important for the safety and therefore we strongly advise the customers to read this Manual very carefully before the operation Also be sure that this Manual is properly kept and ready to be read at any time whenever necessary Example ...

Страница 3: ...e product out of the conditions specified Otherwise this may cause electricity leakage electric shock fire and or water leakage This product is for industrial application and therefore do not use for home application Caution Items when moved Caution Mark In case the product is lifted by human being it should be done not only by bending the waist but also bending the arms Otherwise the waist may be...

Страница 4: ... Equip with an earth device and apply leakage breaker to be purchased separately In case any trouble electric leakage or static electricity happens it may cause electric shock The flammable liquids such as kerosene gasoline solvent and medicines and or the explosive should not be sucked and or used nearby them These may cause explosion or fire etc The explosive materials such as aluminum magnesia ...

Страница 5: ...ay cause short circuit electric shock and or fire Do not suck harmful materials such as dioxins and asbestos etc which may be harmful to the human beings These may cause environmental problem and or health problem Do not use the product under the temp condition with higher than 60 The mis use may cause the fire The acceptable temp condition for the operation is between 0 60 Do not use under high h...

Страница 6: ...of electricity shock unless the earth device is equipped Be sure to apply 200V 240V AC This may cause fire due to electricity shock or short circuit In case the pipe or hose is clogged by anything the product may stop sucking when the float goes up In such a case immediately shut the switch off This may cause some trouble due to the increase of motor temperature Do not operate the product at the p...

Страница 7: ... suck cement powder plastic power which are to be solidified conductive fine dusts and medicines metal powder carbon powder The product may cause fire due to electricity shock or short circuit Do not use the bubbled liquid Due to the bubble the float may not always work properly In case liquid is overflown the buddle from the outlet may cause electricity shock short circuit or soil clothes Also th...

Страница 8: ...d or wrapped condition The wire may be heated resulting in fire Be sure that the wire is properly stretched before used The dirt on electric wire should be periodically wiped off by dry towel In case the dirt on wire remains the insulation failure due to moisture may cause fire The dust or pin should not be adhered to the plug This may cause fire due to electric shock or short circuit Do not leave...

Страница 9: ...lectric leakage or injury The cleaning thinner can be used only at total fire ban area only Otherwise this may cause fire or accident Always keep proper ventilating when the thinner is used for filter cleaning Otherwise this may cause toxic sickness due to thinner The above in this Operation Manual does not cover all possible items for the cases of Danger Warning and or Caution Though our product ...

Страница 10: ...ct In case fuse 15A is not sufficient enough contact our service shop or distributor Model EVC 550 Power Source 230 V Electric Cousumption 1 05 kW Current 4 6 A Max Blowing volume 3 3 min Max Vacuum Pressure 20 5 KPa Hose Inner Dia φ32 Length2m Electric Wire Length 5m with earth grip Size of the Product External Dia φ320 Height400mm Weight 8 2 kg ...

Страница 11: ...3 Name of each part and accessary 0 To repair the part which can not be separately purchased please contact service shop dealer ...

Страница 12: ...Rubber Plug To be purchased 1 22 Cable with rubber cap To be purchased 1 5m 23 Round Head Screw with cross hole SUS304 2 M4 8 P1 24 Saddle FC 1 25 Bolt with hexagon hole SUS304 6 M5 10 26 Plate SPHC etc 1 27 Hexagon Nut SUS 10 M5 28 Filter Pressure SUS304 1 29 Filter Motor 2pcs set Polyester Acryl 2 30 Rubber Packing CR Rubber 1 31 Lower body SPHC etc 1 32 V Packing NBR 1 33 Water Proof Cover SPHC...

Страница 13: ...Use 1 How to assemble hose and nozzle Assemble according to the below instruction Insert the hose deeply into inlet at lower body Inlet at lower body and fix the hose by large hose clip Insert the nozzle into the head of hose The Hose and the nozzle are fixed by large hose clip ...

Страница 14: ...uipped at wire head Make sure the earth is grounded to avoid electric shock After used be sure electric wire is pulled out from outlet to avoid the electric shock Electric wire should be fixed by wire clip and firmly wounded so that it will not be twisted Wire Clip Earth Clip ...

Страница 15: ...se happens take care as follows For the case of water drop Without sucking anything keep no load operation for a few minutes to make the filter motor dry For the case of oil drop Take the filter motor out and make it clean with washing oil After properly dried up place the filter motor to the original position OFF Switch OFF to stop sucking g ON Switch ON to start sucking ...

Страница 16: ... below shows how to take out install the filter Caution In case the dusts are collected be sure to apply our standard filter attached When the liquid is collected be sure to take the filter out first 5 Float Ball to prevent overflow In case water or mud etc remains in the tank the float ball will goes up stopping sucking operation In case sucking operation is stopped shut the switch off and then t...

Страница 17: ...agon bolt is changed be sure to use the wrench for hexagon bolt application 1 How to take the filter motor out Take six bolts out as shown below and then the upper body can be removed so that to check if the dusts unreasonably remain or the filter motor should be washed Filter Motor 2 pcs Filter Pressure Rubber Packing Hexagon Bolts M5 10 6 pcs Upper Body ...

Страница 18: ...ectric wire and contact service shop for the replacement If the earth grip is not loosened or working normally Replace the electric wire and contact service shop for the replacement If the switch protective rubber is not torn Replace the switch and contact service shop If the hose is deformed or not torn Replace the hose If the hose is not clogged with anything Remove the rubbish immediately If th...

Страница 19: ...pplied Even though the inspection and or maintenance is regularly and properly implemented at the customers the mechanical problem or the damage happens due to our improper designing or inferior assembly manufacture in our factories within the above period However our assurance does not cover any expenses or any loss related with the mechanical problem or damage In case of free replacement and or ...

Страница 20: ...to wrongful handling different use instructed in the Manual 2 Any problem which is due to the repair disassembly or remodel carried out not by our service shop 3 Any problem due to improper maintenance or poor maintenance while stored 4 No purchase evidence such as invoice receipt etc is presented 5 Parts consumption which have been too heavily used For any repair and or after service during assur...