Aquasub engineering AQUA GROUP AQUATEX AV Series Скачать руководство пользователя страница 1

AQUASUB ENGINEERING

TUDIYALUR POST, COIMBATORE - 641034

TEL : 0422 - 2642484, E-mail : [email protected]

Website : www.aquagroup.in

VERTICAL MULTISTAGE HIGH PRESSURE PUMPS

AV, AVI, AVN

 

SERIES

OPERATION MANUAL

Содержание AQUA GROUP AQUATEX AV Series

Страница 1: ...AQUASUB ENGINEERING TUDIYALUR POST COIMBATORE 641034 TEL 0422 2642484 E mail marketing aquagroup in Website www aquagroup in VERTICAL MULTISTAGE HIGH PRESSURE PUMPS AV AVI AVN SERIES OPERATION MANUAL...

Страница 2: ...plingwithequallysizedsuctionanddischargeports Stage construction with Stainless Steel impellers diffusers and outer tube pump shaft and motor shaft are of IEC Standards All wetted parts of pump are ma...

Страница 3: ...PARTS LIST AV 1 3 5 10 15 20 AVI AVN 1 3 5 10 15 20 AV 32 45 64 90 AVI AVN 32 45 64 90 44 57 48 82 36 37 18 12 24 59 36 37 56 18 12 24 59 44 57 38 82 62 53 36 48 14 37 57 18 12 24 82 42 59 53 36 48 14...

Страница 4: ...14 Bearing ring 17 Bearing ring 18 Impeller 24 Neck ring 36 Motor bracket Top casing 37 Shaft 42 Bottom bearing ring 48 Outer tube 53 Motor bracket 56 Top casing 57 Mechanical seal 59 Inline casing 62...

Страница 5: ...n 1 Pipe support Support piping system properly to avoid stresses on connections 2 Isolating valves Install isolating valves for easy access before the pump intake and after the pump discharge 3 Use f...

Страница 6: ...fice in your area No Description 8 If it is necessary to increase the diameter of the suction pipe place an eccentric reducer between the isolating valve and the flexible pipe section 9 Using elbows w...

Страница 7: ...s working If there any disturbance in operation re prime the pump Check the current drawn by the motor If necessary adjust the setting of the thermal relay Thermal relay is provided in single phase 0...

Страница 8: ...otor should be lubricatedwithhightemperaturelithium basedgrease If the pump and motor are not used frequently with long intervals of non operation then it is recommended that the motor to be greased F...

Страница 9: ...COUPLING ADJUSTMENT AV AVI AVN 10 15 20 SERIES...

Страница 10: ...COUPLING ADJUSTMENT AV AVI AVN 34 45 62 90 120 150 SERIES...

Страница 11: ...try starting again d Pump is jammed by an obstruction Check and clean obstruction from system e Contacts in overload are faulty Replace motor starter contacts f The motor winding is defective Replace...

Страница 12: ...is not constant a The pump draws in air or the inlet pressure is too low Improve the suction conditions b The pump or the suction side of the piping system partly blocked by foreign bodies Clean the p...

Страница 13: ...Aquasub Engineering as well as expenses incurred in connection with deputing of service personnel technicians towards to and fro travel conveyance and other incidentalsetc willbebornebythecustomer 4 T...

Страница 14: ...42484 E mail marketing aquagroup in Website www aquagroup in OTHER BUILDING SERVICES PRODUCTS Hydropneumatic Pumping System Domestic Booster System Water Transfer Sewage Drainage Construction Dewateri...