SPECIAL FUNCTIONS
TO ACTIVATE 24 HOUR BOOST - Automatic super-chlorination
1. The unit must be in the AUTO mode.
2. Hold the UP button until the display flashes and the rotating boost mode
indicator will begin.
(The pump & chlorinator will operate at full power for 24Hrs. regardless of
current settings and then switch back to the normal auto mode settings for both
time & output)
• Ideal for periods where pool encounters heavy bather loads
• Avoids the necessity to manually switch unit On and then Off after extended
chlorination periods
PUMP PROTECTION MONITOR
Optional function that protects the pump from operating with little or no water. These
conditions often exist and may damage the pump. The pump protection function uses
the gas sensor in the cell to detect the absence of sufficient water and after a delay
period, the pump is switched off.
TO SET MONITOR:
Hold the
DOWN
button until the display flashes. If a zero is
displayed, this indicates that the pump protection monitor is not activated. While the
display is flashing, use the UP/DOWN buttons to activate the monitor and set the
delay in minutes that you would allow the pump to run in a starved of water condi-
tion. Once set, the display will lock in the value and return to the live display within 30
seconds.
Example: If a delay of 4 minutes is set, the pump will automatically switch off if the
chlorinator cell detects a low water flow for a period of 4 minutes. The message
FLO
FAIL-OFF
will scroll across the display indicating this condition.
If the unit is in the
AUTO
mode, the system will retest the condition at the next ON
time period, if the condition no longer exists, the pump will continue to operate as per
normal. Pushing the mode button will also cancel the condition enabling you to oper-
ate the system and determine what the problem is.
All pools have different hydraulic characteristics and risk levels with respect to the
possibility of pump damage occurring due to lack of water. Pumps also have different
tolerance levels to operating dry or in a starved condition. The average delay time
would be from 3 to 6 minutes but we would recommend you seek advice from the
pump manufacturer or a pool professional.
To
deactivate
the pump monitor, hold the
DOWN
button until the flashing delay time
is on display. Use the
DOWN
button to reduce the time to zero, this disables the
protection monitor.
Note: Remember, if you backwash the filter, vacuum to waste or perform
any other function that bypasses water through the cell, the flow fall
function will switch the pump off after It has timed out since it recognizes
no water flow. Simply push the mode button to reset or deactivate pump
monitor.
20
9
Wiring instructions for AquaPower-Plus
All AquaPower-Plus systems are set up to operate at 220 volt from the factory.
Above fround units are set up to operate on 110 volt only. (For above ground
units refer to wiring instructions for above gorund units only.)
To convert a system from 220 volts to 100 volts use the instructions below.
220 Volt Wiring
1. Remove access panel on front of power box.
2. Knock out appropriate hole in bottom of box to match your
conduit size.
3. From your 220 volt power source, install your 2 power lines to terminal 1 and
terminal 4.
Timer wiring for 220 volt pumps
1. Knock out appropriate hole in bottom of box to match your
conduit size.
2. Install (2) power lines to terminal 7 and terminal 8 from your
220 volt pump.
3. Install your ground wire to terminal 6.
Wiring of unit is complete.
110 Volt Wiring
Conversion to 100 volts (In ground pools only!)
1. Remove access panel in front of power box.
2. Knock out appropriaate hole bottom of box to match your conduit size.
3. Remove the (2) jumpers from terminals 2 & 3. Reinstall theses jumpers on
terminals 1 & 2 and terminals 3 & 4.
4. Install your black power line to terminal 4.
5. Install your white neutral line to terminal 1.
6. Install your ground wire to terminal 5.
Timer wiring for 110 Volt pumps.
1. Knock out appropriate hole in bottom of box to match your conduit size.
2. Install your black pump wire to terminal 8.
3. Install your white wire to terminal 7.
4. Install your ground wire to terminal 6.
Wiring of unit is complete.