Instruction Sheet
AquaMotionHot One AMH3K-7 (with timer)
AMH3K-7N (N- no timer)
Point of Use Hot Water Recirculation System
(For Tank Systems)
THANK YOU for purchasing a new Aquamotion Hot System!
For optimum reliability and performance please follow the
installation instructions outlined below.
NOTE:
Please note that this is not an anti-scald unit. There may
be some warm water in the cold water line under the sink where
the circulator is installed. Once the cold water line is opened, the
warm water will disappear in a short time. (Longer hot water lines
may result in longer time for hot water to reach the sink.)
APPLICATION
The AquaMotionHot One circulators are designed to deliver hot
water instantly at the point of use (under sink). Water savings
can be as great as 12,000
– 15,000 gallons per year with 4-5
taps in a home. The AMH3K-7 (N) circulator together with the
Aquamotion
“On Call™” accessories are designed to be user
friendly, reliable and to produce a professional installation.
WARNING:
Risk of electric shock. The AMH3K-7 (N) kits are
supplied with a grounding conductor and grounding type
attachment plug. To reduce the risk of electric shock, be certain
that it is connected only to a properly grounding type receptacle.
WARNING:
When installing The AMH3K-7 (N) observe all
applicable electrical and plumbing codes.
WARNING:
To avoid electrical shock, disconnect power prior to
connecting or disconnecting The AMH3K-7 (N).
WARNING:
Risk of electric shock. The AMH3K-7 (N) has not
been investigated for use in swimming pool or marine areas.
WARNING:
The AMH3K-7(N) is acceptable for indoor use only.
Employer uniquement a l’interieur.
CAUTION:
The AMH3K-7(N) has been evaluated for use with
water only. The suitability of The AMH3K-7(N) for use with liquids
other than water is the responsibility of the end user.
SYSTEM REQUIREMENTS
Minimum water pressure 20 psi, Maximum water pressure 125
psi, Maximum water temperature 176F (80 C)
SHIPMENT INSPECTION
Examine all components carefully to ensure they are all present
and they have not been damaged in transit to you. Care should
be taken to avoid dropping or mishandling the AMH3K-7(N).
Damage to the AMH3K-7(N) may occur if it is dropped.
KIT CONTENTS
The AMH3K-7(N)
“Hot One” package includes:
(1) Pump, model AM7-SU1LAM(T1) complete with mounting
bracket, pre-wired 10-foot flexible cord, and built-in Aquastat
(1) Union tail piece without red marking.
(1) Union tail piece with red marking.
(2) Union nuts.
(2) Union gaskets.
(2) Flex hoses 1/2” NPS x 1/2” NPS 24 inches long.
(2) Tee,
3/8” compression x 1/2” NPS x 3/8” compression.
REQUIRED TOOLS
(2) -
Pipe wrenches which open to at least 1 1/2”
(1) - Adjustable wrench which opens to at least 1
”
*Teflon tape is Not required.
INSTRUCTIONS for AMH3K-7(N) (see Fig. 1)
1.
Locate the hot and cold shut off valves (angle stops)
typically located near the faucet(s) under the counter.
2.
Close both shut off valves and disconnect the flexible
hoses attached to each valve by turning the nut at the end
of the hoses counter-clockwise.
3.
Install one Tee at each valve. Connect the female port of
the Tee to the port on the valves from which you have just
disconnected the hoses.
4.
Connect the hoses which you had disconnected from the
valves to the top port of the Tee.
MAKE SURE YOU
CONNECT THE HOSES TO THE SAME VALVE TO
WHICH THEY HAD ORIGINALLY BEEN CONNECTED.
5.
Attach the unions (gaskets, nuts and tail pieces) to the
pump casing. The gaskets must be located between pump
casing and tail piece
.
MAKE SURE THE TAIL PIECE
MARKED RED IS MATCHED UP WITH THE RED
MARKING ON THE INLET SIDE (THAT IS OPPOSITE
DIRECTION OF ARROW) OF THE PUMP.
You will need
two pipe wrenches that
open to at least 1 1/2” inches.
Firmly tighten the two union nuts to avoid leaks. Do not
install the pump upside down.
6.
Place the pump into its intended location with the bracket
on the floor and fasten with screws if necessary. It is also
possible to install the pump horizontally but make sure that
the wall to which it is fastened is sturdy enough to support
the pump
NOTE: Be sure the arrows on the pump
point to the cold water side.
7.
Install the flex hoses by attaching one end to the remaining
port of the Tee and the other end to the pump.
MAKE
SURE THE HOSE ATTACHED TO THE HOT
VALVE IS
CONNECTED TO THE INLET SIDE (THAT IS THE
OPPOSITE DIRECTION OF THE ARROW) OF THE
PUMP. MAKE SURE THE HOSE ATTACHED TO THE
COLD VALVE IS CONNECTED TO THE DISCHARGE
SIDE (THAT IS THE SIDE THE ARROW IS POINTING
TO) OF THE PUMP.
8.
Open the valves. Check for leaks.
9.
Plug in the cord to any convenient grounded, 115 volt
outlet. Your kit contains a circulator with a built-in timer.
Follow the step by step directions on the timer instruction
sheet to program the timer to meet your hot water needs.
10.
The system will settle in 2 to 3 hours. Opening faucets will
help release any trapped air.