Mounting
CAUTION
The surfaces of the device and the medium may be hot.
Risk of burns!
Carry out work only on cooled systems.
Work may only be performed by authorized specialists in accordance with the
applicable regulations.
Use appropriate protective equipment.
WARNING
The pipe and the device may be under pressure.
Risk of severe injury!
Carry out work only on non-pressurized systems.
When working on the device watch out for leaking medium.
Work may only be performed by authorized specialists in accordance with the
applicable regulations.
Use appropriate protective equipment, particularly safety goggles.
Flow meter installation
Easy access for reading the flow meter and controlling the ancillary equipment is important.
Provided that the arrow on the housing is in the direction of flow
, the flow meter can be
installed in any position without any special modifications.
The electronic display unit is rotateable in 90° steps to the installed position.
Exception
: upside down installation.
Flow conditioners are unnecessary.