AQ150

Thermostatic bar mixer valve

with adjustable head

Installation guide

AQ150:Midas  15/9/15  12:15  Page 1

Содержание AQ150

Страница 1: ...AQ150 Thermostatic bar mixer valve with adjustable head Installation guide AQ150 Midas 15 9 15 12 15 Page 1...

Страница 2: ...tallation commences Connections This product is designed for conventional supplies with HOT on the Left and COLD on the Right as viewed from the front Supply lines must be flushed clear of any debris...

Страница 3: ...the nearest convenient draw off point Account must be taken of pressure drops that may occur when other draw off points are used while the shower is in use A typical layout is shown overleaf Boosted g...

Страница 4: ...4 Typical system diagrams Typical pumped system installation Typical gravity system installation 0 5m 1m 1 5m 0 5m 1m 1 5m Water level Water level AQ150 Midas 15 9 15 12 15 Page 4...

Страница 5: ...Typical system diagrams continued Typical combination boiler system installation Typical thermal storage unit system installation Typical UVHW system installation 5 AQ150 Midas 15 9 15 12 15 Page 5...

Страница 6: ...6 Please note Literature not shown Components may vary Components AQ150 AQ150 Midas 15 9 15 12 15 Page 6...

Страница 7: ...rk during the making good process Remove the caps prior to connecting the shower valve In addition to the guide below it is essential that the written instructions overleaf are read and understood and...

Страница 8: ...thin bead of mastic if re quired 1 Ensuring the handset cradle is on the left hand side of the rail pass the rail through the handset holder whilst keeping the slider button depressed 2 Fit the forme...

Страница 9: ...ct position to accept the fixed riser wall stay support 5 Screw the wall fixing bracket to the wall using the screws provided Place the cover plate over the wall fixing bracket 9 6 Insert the lever of...

Страница 10: ...9 Ensuring the hose washers are in the correct position secure the handset to the hose and place into the handset holder The tension of the handset station to the handset holder is factory set Howeve...

Страница 11: ...eeds 10 bar install a pressure reducing valve PRV in accordance with the installation guide Airlock in the hot water supply Water temperature swings regularly between hot and cold Flow rate is poor an...

Страница 12: ...sa co uk Republic of Ireland Sales enquiries 01 864 3363 Service enquiries 01 844 3212 Please note that calls may be recorded for training and quality purposes The company reserves the right to alter...