1.3. 

Limitation of liability 

The legally prescribed liability conditions apply. Excluded from liability are: 

  failure to observe this manual 

  improper use 

  use of untrained staff 

  use of unauthorised replacement parts 

  conversions performed by the operator, which have not been discussed with 

and authorised by the manufacturer 

Furthermore, the general terms and conditions also apply. 

 

1.4. 

Copyright 

Copyright applies to this manual. 

© Copyright by AquaDuna GmbH & Co. KG (2019) 

The transfer of this manual to third parties, reproduction in any way  - even in the 
form of excerpts - as well as the use and/or disclosure of the contents without written 
permission is not allowed. 

In individual cases, for in-house use by the operator or for the purposes of training, 
it is permissible to distribute the manual to third parties or to reproduce it. 

 

1.5. 

Warranty 

The legally prescribed warranty period of one year shall apply. Supplementary war-
ranty conditions may be referred to in the sales documentation. 

 

 

 

Содержание DUNOS R

Страница 1: ...Assembly Manual DUNOS R DUNOS RW...

Страница 2: ...ls used 4 1 3 Limitation of liability 5 1 4 Copyright 5 1 5 Warranty 5 2 SAFETY 6 2 1 Proper use 6 2 2 Operating conditions 6 2 3 Staff qualifications 7 2 4 Duties of the operator 7 3 TECHNICAL DATA 8...

Страница 3: ...ject to technical modifications Copyright by AquaDuna GmbH Co KG 2019 All rights reserved Contact www aquaduna com 7 INTEGRATION AND ACTIVATION 13 7 1 Integration into a cleaning facility 13 7 2 Activ...

Страница 4: ...ation and maintenance of the appliance The basis of working in safety is the observance of all safety notices provided The manual is an essential part of the product and must be kept freely available...

Страница 5: ...by the operator which have not been discussed with and authorised by the manufacturer Furthermore the general terms and conditions also apply 1 4 Copyright Copyright applies to this manual Copyright...

Страница 6: ...proper use of the rotation cleaner the observance of the fol lowing conditions is essential with non observance carrying the threat of severe injury The rotation cleaners may only be operated in close...

Страница 7: ...handling rotating and spraying devices must have been instructed on the hazards connected with these appliances Persons who are not registered as operating staff should not linger within the operatin...

Страница 8: ...t wear free during operation The cascades emerging from the slotted nozzles extensively strike the wall of the container The thereby emerging washing down forces remove deposits from the container wal...

Страница 9: ...urements DUNOS R DUNOS R15 R32 R60 R90 Installation diameter min DN 20 DN 40 DN 65 DN 100 Media connection thread IG 1 8 IG 3 8 IG 3 4 1 IG 2 Media connection splint 10 13 18 25 4 29 41 52 Working pre...

Страница 10: ...arrangement of the slotted nozzles the following spraying angles may be achieved 360 270 upper 180 lower 270 upper 180 upper At the customer s request variations to spraying angles may be made 3 9 Spe...

Страница 11: ...4 Installation and commissioning 4 1 Mounting After unpacking the rotation cleaner the cleaner should then be checked over for outer damage If no support tube lance is supplied fully assembled the cl...

Страница 12: ...ota tion cleaner is ventilated For hand guided fittings these are not to be opened abruptly in order to avoid pres sure shocks 5 Operation For operation in automatically cleaning facilities operators...

Страница 13: ...of the facility are familiar with the facility s design It is vital that training in emergency shutdown be given and the necessary elements for emer gency shutdown be known The training of those entru...

Страница 14: ...oducts undergo a final functional test 100 check We thereby ensure that only reliable products are allowed to leave our premises 11 Disposal All materials stainless steels and PEEK used in production...

Отзывы: