background image

 

 

6

 

DUNOS 

/

 

DUNOS 

RW

 Operating Manual

 

AquaDuna GmbH & Co KG / Ferdinand-von-Steinbeis-Ring 31 / 75447 Sternenfels / Germany 

Telephone: +49 (0)7045 204980 / 

www.aquaduna.com

Subject to technical modifications. 

© Copyright by AquaDuna GmbH & Co. KG (2019) All rights reserved. Contact: www.aquaduna.com 

 

2.  Safety 

2.1. 

Proper use 

Rotation cleaners are intended for the internal cleaning of enclosed containers.  

Operation outside of a container can lead to severe injury from the high 
impact of the emerging liquid. The cleaning agent would additionally be 
widely dispersed into the environment. 

The pre-conditions for safe operation of the rotation cleaner may be 

found in the following chapter, Operating conditions! 

Another  or  derived  usage  is  not  deemed  to  be  approved  usage  and  AquaDuna 
GmbH & Co KG is not liable for any consequent damage. 

 

2.2. 

Operating conditions 

For the proper use of the rotation cleaner, the observance of the fol-
lowing  conditions  is  essential,  with  non-observance  carrying  the 
threat of severe injury. 

 

  The rotation cleaners may only be operated in closed containers. 

  The rotation cleaner should be operated with a 500µm prefilter. 

  The  bearing  of  the  rotation  cleaner  is  hydrodynamic,  therefore the  rotation 

cleaner must not be operated with air or steam.  

  All media piping should be ventilated.  

  When installing the rotation cleaner inside a container, e.g. a tank, it should 

be  observed  that  the  distance  of  the  rotation  cleaner  to  the  wall  of  the 
container or fittings is sufficient, so that any contact may be excluded.  

  All mechanical connections should be secured against self-loosening. Before 

commissioning, the rotation cleaner should be checked for smooth running 
and firm positioning. 

  The permissible environmental temperature for operating the rotation cleaner 

is 4-138°C, the maximum permissible temperature of the cleaning agent is 
97°C. 

 

The operator is responsible for observance of the conditions. 

 

Содержание DUNOS R

Страница 1: ...Assembly Manual DUNOS R DUNOS RW...

Страница 2: ...ls used 4 1 3 Limitation of liability 5 1 4 Copyright 5 1 5 Warranty 5 2 SAFETY 6 2 1 Proper use 6 2 2 Operating conditions 6 2 3 Staff qualifications 7 2 4 Duties of the operator 7 3 TECHNICAL DATA 8...

Страница 3: ...ject to technical modifications Copyright by AquaDuna GmbH Co KG 2019 All rights reserved Contact www aquaduna com 7 INTEGRATION AND ACTIVATION 13 7 1 Integration into a cleaning facility 13 7 2 Activ...

Страница 4: ...ation and maintenance of the appliance The basis of working in safety is the observance of all safety notices provided The manual is an essential part of the product and must be kept freely available...

Страница 5: ...by the operator which have not been discussed with and authorised by the manufacturer Furthermore the general terms and conditions also apply 1 4 Copyright Copyright applies to this manual Copyright...

Страница 6: ...proper use of the rotation cleaner the observance of the fol lowing conditions is essential with non observance carrying the threat of severe injury The rotation cleaners may only be operated in close...

Страница 7: ...handling rotating and spraying devices must have been instructed on the hazards connected with these appliances Persons who are not registered as operating staff should not linger within the operatin...

Страница 8: ...t wear free during operation The cascades emerging from the slotted nozzles extensively strike the wall of the container The thereby emerging washing down forces remove deposits from the container wal...

Страница 9: ...urements DUNOS R DUNOS R15 R32 R60 R90 Installation diameter min DN 20 DN 40 DN 65 DN 100 Media connection thread IG 1 8 IG 3 8 IG 3 4 1 IG 2 Media connection splint 10 13 18 25 4 29 41 52 Working pre...

Страница 10: ...arrangement of the slotted nozzles the following spraying angles may be achieved 360 270 upper 180 lower 270 upper 180 upper At the customer s request variations to spraying angles may be made 3 9 Spe...

Страница 11: ...4 Installation and commissioning 4 1 Mounting After unpacking the rotation cleaner the cleaner should then be checked over for outer damage If no support tube lance is supplied fully assembled the cl...

Страница 12: ...ota tion cleaner is ventilated For hand guided fittings these are not to be opened abruptly in order to avoid pres sure shocks 5 Operation For operation in automatically cleaning facilities operators...

Страница 13: ...of the facility are familiar with the facility s design It is vital that training in emergency shutdown be given and the necessary elements for emer gency shutdown be known The training of those entru...

Страница 14: ...oducts undergo a final functional test 100 check We thereby ensure that only reliable products are allowed to leave our premises 11 Disposal All materials stainless steels and PEEK used in production...