AQUA-ECB-1
Operating manual
(140-2110-001 DE11)
Control for swimming pool covers :
for all drives of the Aquadeck series with integrated
pulse generator
.
Страница 1: ...AQUA ECB 1 Operating manual 140 2110 001 DE11 Control for swimming pool covers for all drives of the Aquadeck series with integrated pulse generator...
Страница 2: ...ming and parameterisation 5 5 Drive selection 5 6 Setting of the end positions 6 Fine tuning of the positions 7 7 Operating mode 7 8 Speed setting 7 9 Normal mode 7 10 List of the menu functions 8 11...
Страница 3: ...programming unit which can be connected on the board Further function settings can be made in a user friendly way by means of a rotary button S4 The programming is protected against power failure Addi...
Страница 4: ...Danger from electric current When connecting the control there is the danger of an electric shock Before connecting the control it must be switched to zero potential Before accessing the connecting t...
Страница 5: ...ng mode Keep the rotary button S4 pressed for three seconds 2 Select the main menu By rotating the rotary button S4 set the respective numerical code of the desired menu and confirm the selection by p...
Страница 6: ...f it is travelled in CLOSE direction first the CLOSE end position must be stored first and afterwards the OPEN end position If a travel button has already been operated after activating the programmin...
Страница 7: ...n automatic mode the system operates after command initiation automatically until the end positions are reached and can only be stopped by a stop command For each travel direction the selection dead m...
Страница 8: ...Cover in CLOSE position 10 List of the menu functions The functions listed below can be set by means of the rotary button S4 Please perform the desired menu settings before commissioning Menu no Main...
Страница 9: ...s no function 1 Position report OPEN 2 Position report CLOSE 3 System is travelling 33 Running time of the cover After expiration of the set time the system stops Factory setting 15 minutes 0 30 minut...
Страница 10: ...lly the numbers in the right hand segment reveal the number of cycles as a numeral Example 0003526 for 3526 cycles 92 Display the last errors The last 4 errors that have occurred are displayed 94 Disp...
Страница 11: ...ntrol Install a chopper resistor 24 Motor overload Drive is blocked Check the unobstructed movement of the system In case of a freely moving system maybe an insufficiently dimensioned drive 25 Motor t...
Страница 12: ...protect the control a current monitor is integrated additionally When exceeding the current limit value provided for the set drive the control reduces the speed of the drive In doing so the impermiss...
Страница 13: ...the system must be travelled into a safe state Subsequently the system must be repaired After having used the emergency mode reprogramming of the end positions is necessary 15 Accessories A remote pro...
Страница 14: ...Buismotor Tubemotor Aqua ECB M 1 rood red M 2 zwart black Br1 3 grijs grey Br2 4 grijs grey 5 bruin browne A 6 geel yellow B 7 groen green 8 blauw bleu Aansluitschema 5 6 7 1 3 4 8 2...
Страница 15: ...Externemotor Externalmotor Aqua ECB M rood red M zwart black geel yellow A groen green B wit white bruin brown Aansluitschema...
Страница 16: ...SLEUTELSCHAKELAAR KEYSWITCH Aansluitschema L LA 1 3...