2.4 Irrigation and Storm Run-Off
l
Irrigation water may damage heat pump components. Direct irrigation water away from the heat pump.
l
The heat pump will withstand normal rainfall. Do not allow a roof slope to direct rainwater onto the heat pump.
Have a gutter installed on the roof edge to direct this water away from the heat pump. Or install the heat pump in
another location.
2.5 Water Flow Rates
Maintain water flow rates as indicated. Please note, these specifications relate to the heat pump only. Code-
specified whole system turnover rates must be satisfied.
NOTICE
Failure to heed the following may result in damage to equipment.
l
Water flow exceeding maximum flow rates will negatively affect the total pool filtration performance and may
damage the heat pump. This will not be covered under the equipment warranty.
MODEL
HEAT EXCHANGER TYPE
FLOW RATES
MINIMUM
MAXIMUM
SQ120R
Titanium ThermoLink
®
30 GPM (113.6 L/min)
70 GPM (265 L/min)
SQ125
Titanium ThermoLink
®
30 GPM (113.6 L/min)
70 GPM (265 L/min)
SQ145
Titanium ThermoLink
®
30 GPM (113.6 L/min)
70 GPM (265 L/min)
SQ166R
Titanium ThermoLink
®
30 GPM (113.6 L/min)
70 GPM (265 L/min)
SQ225
Titanium ThermoLink
®
30 GPM (113.6 L/min)
70 GPM (265 L/min)
T035
Titanium Tube-in-Tube
20 GPM (75.7 L/min)
45 GPM (170 L/min)
T055
Titanium Tube-in-Tube
20 GPM (75.7 L/min)
45 GPM (170 L/min)
T075
Titanium Tube-in-Tube
20 GPM (75.7 L/min)
45 GPM (170 L/min)
T090
Titanium ThermoLink
®
30 GPM (113.6 L/min)
70 GPM (265 L/min)
T115
Titanium ThermoLink
®
30 GPM (113.6 L/min)
70 GPM (265 L/min)
T135
Titanium ThermoLink
®
30 GPM (113.6 L/min)
70 GPM (265 L/min)
T170
Titanium Tube-in-Tube
30 GPM (113.6 L/min)
70 GPM (265 L/min)
2
-
M
ai
nt
ena
nc
e
Содержание HeatWave SuperQuiet SQ120R
Страница 2: ......
Страница 11: ...Page 8 1 Operation ...
Страница 13: ...Page 10 1 Operation ...
Страница 17: ...Page 14 Set Efficiency Mode to 24 Hour 1 Operation ...
Страница 18: ...Page 15 Set Efficiency Mode to Filtration Schedule 1 Operation ...
Страница 19: ...Page 16 1 Operation ...
Страница 21: ...Page 18 Configure for Call mode 1 Operation ...
Страница 22: ...Page 19 Configure for Flex mode 1 Operation ...
Страница 53: ...Page 50 Model Number Example 4 Appendix ...
Страница 58: ......