Page - 28
Typically a smart bus controller will have four wires on its smart bus for a heat pump. The
power and ground (usually the 1st and 4th wire) are not used.
Figure 2
Figure 3
5. If dip-switch settings are required, configure them on the external controller now.
DANGER
Failure to heed the following will result in injury or death.
l
Deactivate power to the external controller while setting dip-switches
Example - Jandy AquaLink
®
:
This external controller has dip switches. Confirm they are properly
positioned to operate a heat pump.
l
Set dip-switch "S2" #1 to "ON". The solar option is to be used for the
heat pump.
l
Check Jandy documentation for any further dip switch settings.
6. If additional sensors are required on the external controller, install them on the external controller now.
Example - Pentair EasyTouch
®
and Pentair IntelliTouch
®
:
Some controllers require an additional sensor be connected
to the external controller's power supply circuit board at the
solar connection point. The sensor is not used but will show
an error if not connected.
7. Reinstall electrical access panels on both the heat pump and external controller.
8. Reactivate power to heat pump and external controller.
9. Configure the heat pump to accept external controller signal. See "
Configure for Smart Bus Controller
1
-
Ins
ta
ll
at
ion
Содержание HeatWave SuperQuiet SQ120R
Страница 2: ......
Страница 28: ...Page 24 Configure Call Flex Enter Installer Menus then proceed 1 Installation ...
Страница 33: ...Page 29 Configure for Smart Bus Controller Enter Installer Menus then proceed 1 Installation ...
Страница 36: ...Page 32 Configure 2 wire controller Enter Installer Menus then proceed 1 Installation ...
Страница 40: ...Page 36 1 Installation ...
Страница 41: ...Page 37 Configure for Scheduled Mode Enter Installer Menus then proceed 1 Installation ...
Страница 42: ...Page 38 1 Installation ...
Страница 45: ...Page 41 1 Installation ...
Страница 47: ...Page 43 1 Installation ...
Страница 50: ...Page 46 1 Installation ...
Страница 53: ...Page 49 1 Installation ...
Страница 55: ...Page 51 1 Installation ...
Страница 58: ...Page 54 Turbo Boost 1 Installation ...
Страница 59: ...Page 55 Set Efficiency Mode to 24 Hour 1 Installation ...
Страница 60: ...Page 56 Set Efficiency Mode to Filtration Schedule 1 Installation ...
Страница 61: ...Page 57 1 Installation ...
Страница 63: ...Page 59 1 Installation ...
Страница 65: ...Page 61 1 Installation ...
Страница 84: ...Page 80 Model Number Example 3 Appendix ...
Страница 89: ......
Страница 144: ...Rev L 8 12 13 MASTERTEMP Pool and Spa Heater Installation and User s Guide 55 N TES ...