Aqua TECHNOPOOL PH-RX Скачать руководство пользователя страница 1

TECHNOPOOL

 

 

 

 
Dosing systems for swimming pools 

 

ENGLISH 

 

ADSP7000570 

rev. 2.0 

06/08/2021 

 

1/37 

 

 

 

 

Dosing systems for swimming pools 

 

TECHNOPOOL 

 

TECHNOPOOL PH-RX             TECHNOPOOL 3     

 

 
 

 

     

 

 

For other languages please visit: 

 

                                 

 

                           TECHNOPOOL PH-RX                                                           TECHNOPOOL 3 

 

                                                                            

 

Содержание TECHNOPOOL PH-RX

Страница 1: ...sing systems for swimming pools ENGLISH ADSP7000570 rev 2 0 06 08 2021 1 37 Dosing systems for swimming pools TECHNOPOOL TECHNOPOOL PH RX TECHNOPOOL 3 For other languages please visit TECHNOPOOL PH RX...

Страница 2: ...temperature 13 4 3 Setting of the cyclic dosing pump P1 it is not displayed on pH Rx pH ClJ and pH HP technopool3 13 4 4 Setting the pH pump pH 15 4 5 Setting the redox P2 pump 16 4 6 Setting the chlo...

Страница 3: ...ways cyclic Opening ON and closing OFF schedule of the relay are fixed or proportional to the temperature of the water reached during the latest dosing ON OFF Opening ON and closing OFF schedule is co...

Страница 4: ...ectrode only for Time pH Rx Technopool3 systems and pH Rx A HIRSCHMANN input for chlorine electrode only for pH ClJ Technopool3 systems A HIRSCHMANN input for hydrogen peroxide electrode only for Tech...

Страница 5: ...for any electrical connection All electrical connections must be carried out in compliance with local laws regarding electrical systems CAUTION Verify that the earth system is perfectly functional and...

Страница 6: ...ion of 500mA 2 2 9 Solenoid valve output RELAY Clamp RELAY clamp provides a dry contact not live and it is used to control the solenoid valve To have a voltage on the RELAY clamp equal to the power vo...

Страница 7: ...r installation ref j Put the o ring ref 8 on the injection tube Insert the injection tube inside the PVC tube ensuring that the injection is in the same direction as the pool circulation indicated by...

Страница 8: ...crew the nut with care ref 11 Long probe Installation 120 mm A standard electrode 12x120 mm can be used in that case you must use all the accessories inside the kit Put the nut ref 11 on the probe bod...

Страница 9: ...TECHNOPOOL Dosing systems for swimming pools ENGLISH ADSP7000570 rev 2 0 06 08 2021 9 37 3 0 TECHNOPOOL MENU Tecnopool programming system is divided in 2 menus User and Installer...

Страница 10: ...nopool3 Status Description Active The pump is active Inactive The pump is inactive Flow alarm Flow alarm active Circ Pump Off The recirculation pump is not operating Switch Off The pump switch is set...

Страница 11: ...pool3 Press keys to set manually the values to be dosed and Enter to confirm and activate the dosing of the P2 pump The dosing that can be set is 0 999 ml or 1 0 9 9 litres Rx Cl HP corrector it is no...

Страница 12: ...y the system pH calibration Activates the procedure for the calibration of the pH electrode Rx calibration is displayed on Time pH Rx and pH Rx Technopool3 Activates the procedure for the calibration...

Страница 13: ...ulation of the dosing but only for the display Press keys to set the desired value and Enter to confirm Values that can be set are 5 0 10 0 Man Temperat only if the Temperat Mode is Manual It represen...

Страница 14: ...wo days at h13 00 Manual temperature or with PT100 Qty first Prod Indicates the quantity to be dosed in ml or litres Press keys to set the desired value and Enter to confirm Values that can be set are...

Страница 15: ...d setpoint and Enter to confirm Setpoint values that can be set are 5 0 9 0 pH Work mode pH The operation mode sets the type of solution it is being dosed Acid the pump starts dosing when the value re...

Страница 16: ...nce until Set Point Rx is displayed Set Point Rx The setpoint indicates the value of Rx that is intended to keep Press keys to set the desired setpoint and Enter to confirm Setpoint values that can be...

Страница 17: ...on the display Set Point Cl The setpoint indicates the desired chlorine value Use the keys to set the desired setpoint and then confirm with the Enter key The setpoint that can be set ranges between 0...

Страница 18: ...P appears on the display Set Point HP The setpoint indicates the desired hydrogen peroxide value Use the keys to set the desired setpoint and then confirm with the Enter key The setpoint that can be s...

Страница 19: ...programmed in days Indicates the activation hour If it is left in Auto the activation occurs immediately after the programming Values that can be set are 0 23 hours or Auto Example Sec Prod Qty 400 ml...

Страница 20: ...e pump will dose 4 9 SETTING THE SOLENOID VALVE The operation mode of the control relay of the solenoid valve can be ON OFF or cyclical ON OFF The relay opening and closing is controlled by the redox...

Страница 21: ...pen Press keys to set the desired value and Enter to confirm Values that can be set are 0 59 seconds or 1 60 minutes Relay On T Max Indicates the ON timing of the relay solenoid valve open to the prog...

Страница 22: ...the installer menu and follow the instructions displayed Once carried out the pH 7 calibration rinse the electrode with water so to prevent the pH 4 solution from polluting Once the procedure is comp...

Страница 23: ...instrument Select CI Calibration in the user menu and follow the instructions that scroll on the display When the system acquires the calibration value two parameters regarding the measure are displa...

Страница 24: ...meters regarding the measure are displayed the current value 0 00 20 00 mA the measured hydrogen peroxide value 0 0 500 0 ppm Furthermore the value detected by the DPD4 reference instrument can be ass...

Страница 25: ...the password of the system Press keys to set the value and Enter to move the slider User name Set the name of the client Press keys to select a character and Enter to move the slider Contact assist Se...

Страница 26: ...when the measure nears the setpoint 6 1 SETTING THE ALARMS Select Alarms in the installer menu Contr Dos V1 Enables or disables the dosing when signal V1 occurs signal of the active recirculation pump...

Страница 27: ...s 7 0 WINTER PAUSE It is recommended to work the system with tap water to clean the tube and avoid chemical attacks during the pause period Probes must be removed from the installation during the wint...

Страница 28: ...ment shall not extend or renew the guarantee period Assembly and dismantling costs of the system pumps transportation costs and used materials filters valves etc are borne by the buyer The right to re...

Страница 29: ...Cyclical Relay On 0 s Relay On at the maximum temperature 0 s Relay Off 0 s Relay Off at the maximum temperature 0 s Maximum Temperature for Relay Timing 28 C Stabilisation Time 30 s Stabilisation af...

Страница 30: ...controlled by pH reading Rx pump controlled by Redox reading Rx Technopool3 Time pH It is a system with two peristaltic pumps controlled in the following way P1 pump controlled by timer 1 pH pump con...

Страница 31: ...upplied is slightly affected by the variations in pH range 4 12 pH Description of the chlorine electrode 1 PG7 cable gland 2 Cover 3 O Ring 4 2 pole terminal for the electrical connection 5 Electrode...

Страница 32: ...roove in order to cover the ventilation hole Clean the membrane cover 11 and the cover 15 only for ADELCLJ15 under running water and dry them Fill 11 and 15 only for ADELCLJ15 with the electrolyte sup...

Страница 33: ...e cap without tightening to protect the electrode Attention the membrane must not touch the measure electrode When the probe is to be used again clean the tip of the electrode with the special sand pa...

Страница 34: ...lied to clean just the tip of the dry electrode Hold the special sand paper well and rub the tip of the slightly tilted electrode on the sand paper Then turn the probe slightly and rub it on the paper...

Страница 35: ...TECHNOPOOL PH RX TECHNOPOOL 3 ADSP7000570 rev 2 0 06 08 2021 35 37 ESPLOSO EXPLODED VIEW EXPLOSE DIBUJO...

Страница 36: ...TECHNOPOOL PH RX TECHNOPOOL 3 ADSP7000570 rev 2 0 06 08 2021 36 37...

Страница 37: ...ADSP7000570 rev 2 0 06 08 2021 37 37 For other languages please visit TECHNOPOOL PH RX TECHNOPOOL 3...