Step 3
- Close the front glass
Fig. 17 - Reassembly of the peristaltic tube
5.3 TROUBLESHOOTING
Problem: the pump does not turn on, the LED and display remain off
Solution:
3. Make sure the connection to the electrical network has been set up correctly in accordance with the
information provided on the pump identification plate.
4. The electronic board may be damaged as well: call the support Service.
Problem: the pump works well but it doesn't measure out the product into the swimming pool
Solution:
5. Check the product level.
6. Make sure the foot strainer is not clogged up.
7. Make sure the delivery tube is correctly connected to the check valve, at the injection point of the system.
8. Check the status of the peristaltic tube. If evident malformations are detected, make sure that the material
is compatible with the product being dosed by consulting the chemical compatibility table (
and then go ahead with the replacement
Problem: liquid leaking from the peristaltic tube
Solution:
3. Make sure the delivery and suction tubes are inserted properly and the ring nuts are well tightened.
4. Check the status of the peristaltic tube. If evident malformations are detected, make sure that the material
is compatible with the product being dosed by consulting the chemical compatibility table (see
),
and then go ahead with the replacement
Problem: no alarm has gone off, but the pump is not dosing
Solution:
5. Make sure the switch is not set to OFF.
6. Control that the Delay, Block time or Dosing is over (
End
);
7. Make sure the enabling signal coming from the recirculation pump is active and stabilized;
8. Make sure that the dosing time
tIn
(Timed Cyclic Mode) or the g/cu. m. of Product
G.nC
or the cubic
metres of the pool
P.nc
(Quantity Cyclic Mode) are not equal to 0.
Problem: the threshold of the inhibiting signal cannot be set correctly
(from the
In.t
entry of the
Solution:
3. Check whether the Inhibiting signal is connected correctly.
4. Call the Support Service;