Simpool Pool-T Model
INSTRUCTION AND MAINTENANCE MANUAL
Programmable digital peristaltic pump
ENGLISH
ADSP7000642
rev. 1.0
13/01/2014
52/72
Fig. 13 - Pump Calibration Menu
3.3.4 Resetting Default Parameters
From the
d.P.r
entry you will able to reset the equipment default parameters (refer to the
Default Parameters
); If you choose to reset the initial values, you will go back to the initial display
. See Fig. 14
Once you confirm with
YES
, you cannot go back.
Fig. 14- Default parameter reset
3.3.5 Settings Menu
From the
OPt
entry of the Programming Menu, via the
Enter
key, you can access the
Settings Menu
From the Settings Menu you can carry out the following operations (refer to
Figure 15
):
Set the password to access the programming section
PAS
: with
Enter
you can go to the
“000” selecti
on
page,
with the
▲
and
▼ keys you can increase/decrease the value displayed and with
Enter
you can scroll
to the figure you intend to set. After choosing the new password, press
Enter
for 3 seconds to go back to the
PAS
entry;
Enable the pump stop in case of a
P.St
level alarm: to enter and exit the submenu, use the
Enter
key, use
the
▲
and
▼ keys to choose "
YES/no
";
Select the Relay operating mode
rEL
: to enter and exit the submenu, use the
Enter
key, and
▲
and
▼ to
choose “
YES/no
”;