background image

 

 

 

 

 

 

 

 

MANUALE DI INSTALLAZIONE 

E MANUTENZIONE 

 

OPERATING AND 

MAINTENANCE INSTRUCTIONS 

 

MANUAL DE SERVICE 

ET D’ENTRETIENT 

 

MANUAL USO 

Y MANTENIMIENTO 

 

 

POMPE SERIE / PUMPS SERIES 

POMPES SÉRIE / BOMBAS SERIE 

 

HC 1 

HC 2 

HC 3 

HC 4

 

 

 

Содержание HC 1

Страница 1: ...UALE DI INSTALLAZIONE E MANUTENZIONE OPERATING AND MAINTENANCE INSTRUCTIONS MANUAL DE SERVICE ET D ENTRETIENT MANUAL USO Y MANTENIMIENTO POMPE SERIE PUMPS SERIES POMPES SÉRIE BOMBAS SERIE HC 1 HC 2 HC 3 HC 4 ...

Страница 2: ... characteristics 11 2 4 Electric connection 11 2 5 Hydraulic Connection 11 2 6 Principle of functioning dimensions 12 3 0 MAINTENANCE 12 3 1 General maintenance comments 13 3 2 Periodic maintenance 13 3 3 Basic maintenance procedures 13 3 4 Replacing worn parts 14 3 5 Commonly reported problems 15 WARRANTY CERTIFICATE 15 Dimensions 32 Connection and exploded views 36 ENGLISH ...

Страница 3: ... off and contact our technical assistance for any necessary repairs For a correct functioning it is necessary to use original spare parts and original accessories The producer declines whatever responsibility in reference with break down due to tampering or the use of not original spare parts and accessories The electrical plant has to be in conformity with the rules of the country where it is rea...

Страница 4: ...the supply is adequately earthed and is fitted with a suitably sensitive circuit breaker RCD Connect the pump to the power supply respecting the values you can see on the identify label of the pump and verify the green LED is lit To avoid damages caused by the other equipments TRANSFER pumps do not connect ever the pump directly but use a teleruptor Your pump has 2 internal electrical protection d...

Страница 5: ... that the discharge tubing is fixed correctly to avoid that it does not rub against hard bodies Avoid also use less bends both on discharge and suction tubing Connect the pump to the plant always through the injection valve 1 2 Gm supplied with the installation kit Connect the soft PVC tubing only in suction on the foot filter side instead connect the PE tubing in delivery by verifying that the cu...

Страница 6: ... chemicals are being dosed Sodium Hypo chlorite is particularly difficult this period may need to be reduced and cleaning be carried out more frequently If pumps are not used for long periods scale sediment and encrustation deposits can build up causing the pump to malfunction We highly recommend careful maintenance of the valves by running them under clean water after long periods of non use Alte...

Страница 7: ...ve the cartridge 2 If a ball valve cartridge is fitted remove the whole assembly and replace with a new one taking care to ensure that the arrow is pointing in the direction of flow vertically upwards 3 If lip valves are fitted these can be replaced once again ensuring that they are refitted the correct way up with their open end downwards and the lip part in the direction of flow 4 Refit the nipp...

Страница 8: ...very date to the first purchaser Within the above stated period the producer will supply free of charge any part that upon examination by the producer or by an authorised dealer is disclosed to have been defective in work manship or material or at its option it will repair the parts directly or through authorised workshops It remains anyway excluded from whatever responsibility and obligation for ...

Страница 9: ... SERIE HC 1 A MURO WALL MOUNTING VERSION A PAROI VERCION A PARED Fig 2 SERIE HC 1 CON BASE BASE MOUNTING VERSION AVEC BASE VERSION CON SOPORTE PARA MONTAJE ORIZONTAL DIMENSIONI DIMENSIONS DIMENSIONS DIMENSIONES ...

Страница 10: ... 2 Fig 4 SERIE HC 3 A MURO WALL MOUNTING VERSION A PAROI VERCION A PARED Fig 5 SERIE HC 3 CON BASE BASE MOUNTING VERSION AVEC BASE VERSION CON SOPORTE PARA MONTAJE ORIZONTAL DIMENSIONI DIMENSIONS DIMENSIONS DIMENSIONES ...

Страница 11: ...34 Fig 6 SERIE HC 4 ORIZZONTALE HORIZONTAL Fig 7 SERIE HC 4 VERTICALE VERTICAL DIMENSIONI DIMENSIONS DIMENSIONS DIMENSIONES ...

Страница 12: ...VOLE A LABBRO LIP VALVES Fig 8 COLLEGAMENTI TUBI SUL CORPO POMPA PUMP HEAD TUBING CONNECTIONS SCHÉMA DE MONTAGE CONNECTIONS EXTERNES ESQUEMA DE MONTAJE CONNEXION ESTERNAS Fig 9 SPURGO MANUALE MANUAL PURGE EPURGE MANUELLE ESPURGO MANUAL ...

Страница 13: ...36 Fig 10 SERIE HC 1 Esploso Description Explose Dibujo ...

Страница 14: ... PISTONE PP BIANCA 2 6L PISTON FLANGE 2 6L 6 ADSP6000420 FLANGIA PISTONE PP NERA 5 15L PISTON FLANGE 5 15L 10 ADSP6000441 MANOPOLA PER TRIMMER PT10 TRIMMER KNOB 12 ADSP6000121 CAPPUCCIO PER CONDUTTORE LUMINOSO CAP FOR LED GUIDE 13 ADSP6000120 CONDDUTTORE LUMINOSO LED GUIDE ADSP6000310 CIRCUITO HC100 230V HC100 CIRCUIT 230V ADSP6000329 CIRCUITO HC100 LIVELLO 230V HC100 CIRCUIT LEVEL 230V ADSP600039...

Страница 15: ...38 Fig 11 SERIE HC 2 Esploso Description Explose Dibujo ...

Страница 16: ...RGO AUTOMATICO COMPLETE HEAD 2 15 PVC PVDF CE VT AUTOMATIC DISCHARGE 3 ADSP6000414 DIAFRAMMA PTFE 4 20 BAR PTFE DIAPHRAGM 4 20BAR 4 ADSP6000420 FLANGIA PISTONE PP NERA 5 15L PISTON FLANGE 5 15L 4a ADSP6000487 FLANGIA PISTONE OTTONE 20BAR BRASS PISTON FLANGE 20BAR 4b ADSP6000488 FLANGIA PISTONE PVC 20BAR PVC PISTON FLANGE 20BAR ADSP6000277 MAGNETE COMPLETO HC2 02 18 230V COMPLETE MAGNET HC2 02 18 2...

Страница 17: ...P SS VT ADSP61000S8A CORPO POMPA 2 15 PP GL DT COMPLETE HEAD 2 15 PP GL DT ADSP60000S8A CORPO POMPA 2 15 PP GL VT COMPLETE HEAD 2 15 PP GL VT ADSP6100004 CORPO POMPA 2 15 PP PTFE DT COMPLETE HEAD 2 15 PP PTFE DT ADSP6000169 CORPO POMPA 2 15 PP PTFE VT COMPLETE HEAD 2 15 PP PTFE VT ADSP6100008A CORPO POMPA 2 15 PP VL DT COMPLETE HEAD 2 15 PP VL DT ADSP6000008A CORPO POMPA 2 15 PP VL VT COMPLETE HEA...

Страница 18: ...FRAMMA PTFE 20L PTFE DIAPHRAGM 20L 3 ADSP6000418 DIAFRAMMA PTFE 30 50L PTFE DIAPHRAGM 30 50L ADSP6000421 FLANGIA PISTONE PP BIANCA 2 6L PP PISTON FLANGE WHITE 2 6L ADSP6000420 FLANGIA PISTONE PP NERA 5 15L PP PISTON FLANGE NERA 5 15L ADSP6000509 FLANGIA PISTONE OTTONE 15L BRASS PISTON FLANGE 15L ADSP6000432 FLANGIA PISTONE OTTONE 20L BRASS PISTON FLANGE 20L 4 ADSP6000483 FLANGIA PISTONE OTTONE 30 ...

Страница 19: ... ADSP61000S8A CORPO POMPA 2 15 PP GL DT COMPLETE HEAD 2 15 PP GL DT ADSP60000S8A CORPO POMPA 2 15 PP GL VT COMPLETE HEAD 2 15 PP GL VT ADSP6100004 CORPO POMPA 2 15 PP PTFE DT COMPLETE HEAD 2 15 PP PTFE DT ADSP6000169 CORPO POMPA 2 15 PP PTFE VT COMPLETE HEAD 2 15 PP PTFE VT ADSP6100008A CORPO POMPA 2 15 PP VL DT COMPLETE HEAD 2 15 PP VL DT ADSP6000008A CORPO POMPA 2 15 PP VL VT COMPLETE HEAD 2 15 ...

Страница 20: ...GIA PISTONE PP NERA 5 15L PP PISTON FLANGE NERA 5 15L ADSP6000509 FLANGIA PISTONE OTTONE 15L BRASS PISTON FLANGE 15L ADSP6000432 FLANGIA PISTONE OTTONE 20L BRASS PISTON FLANGE 20L 6 ADSP6000483 FLANGIA PISTONE OTTONE 30 50L BRASS PISTON FLANGE 30 50L 6a ADSP6000487 FLANGIA PISTONE OTTONE 20BAR BRASS PISTON FLANGE 20BAR 6b ADSP6000488 FLANGIA PISTONE PVC NERO 20 BAR 47X32X4 PISTON FLANGE PVC BLACK ...

Страница 21: ...44 Fig 14 Corpo pompa valvole a labbro e sfera Pump head lip and ball valves Corps pompe et clapets à lèvres et bille Cuerpo de la bomba valvulas a labio y a esfera ...

Страница 22: ...007021 OR 106 DUTRAL 6 75 X 1 78 ADSP5007035 OR 106 VITON 6 75 X 1 78 ADSP5007066 OR 106 PTFE 35 ADSP5007102 OR 106 SILICONE ADSP5007049V OR 2010 VITON 2 57 X 1 78 ADSP5007055D OR 2010 DUTRAL 2 57 X 1 78 ADSP5007068 OR 2010 PTFE 41 ADSP5007100 OR 2010 SILICONE 2 57 X 1 78 ADSP6000786 VITE SPURGO CORPO POMPA PP NERO AIR DISCHARGE SCREW PP 42 ADSP6000786P VITE SPURGO CORPO POMPA PVDF AIR DISCHARGE S...

Страница 23: ...la protezione dell ambiente Note on environmental protection After the implementation of the European Directive 2002 96 EU in the national legal system the following applies Electrical and electronic devices may not be disposed of with domestic waste Consumers are obliged by lak to return electrical and electronic devices at the end of their service lives to the public collecting points set up for...

Отзывы: