background image

Set Up Instructions

6. Follow the filter media setup instructions on 
the previous page which apply to your filter. 
Remember to remove all media from the plastic 
bags and rinse in tap water to remove excess 
dust. The simplest way to do this is empty the 
correct media into its basket and run tap water 
through it. Rinse the inside of the canister body 
in tap water. 

DO NOT USE ANY SOAPS OR 

DETERGENTS. 

Fig 4

   

7. Once all the filter media and the canister has 
been washed and the sponges have been 
inserted into the filter baskets place the filter 
media baskets in the correct order (Refer to  
previous page) back into the canister body. 
Ensure the filter inlet pipe has the black sealing 
O-ring at the top of it and that the baskets sit flat 
on top of each other.  Fig 5

8. Ensure the filter grid is then placed back on 
top of the last filter basket. This is very impor-
tant. Fig 6

Fig 1

Fig 2

Fig 3

Fig 4

Fig 5

1. Remove the 2 boxed accessory packs and 
the filter unit from the box.

2. Open the filter unit. To do this release the 4  
clips located on the corners of the filter. Fig 1

3. Lift the head unit off the canister body. Place 
it somewhere safe where it will not be stepped 
on or broken.  Fig 2

4. Take the canister body to the sink. Ensure 
the area is clean and free from detergents. 

5. Remove the filter grid and the filter media 
baskets from the canister. Fig 3

Содержание 1250-R

Страница 1: ...Aquis 1250 R Instruction Manual CanisterFilter ...

Страница 2: ...liance Disconnect the fuse or circuit breaker that supplies the power to the appliance then unplug and examine for presence of water in the receptacle 3 Close supervision is necessary when the appliance is used by or near children 4 Always unplug the water pump from the electrical outlet when not in use before putting on or taking off parts before any type of maintenance or cleaning Never yank the...

Страница 3: ...een assembled This product is shipped to you in a factory sealed carton Should the product malfunction in any way or if the unit is damaged and requires replacement contact the retailer where the product was purchased for inspection Replacement Parts Filter Media Use Reptile One Genuine Spare Parts Only See your local Reptile One Dealer and look for the number listed below for the spare part you r...

Страница 4: ...Recomended Filter Media Set Up Wool Sponge Blue 15ppi Sponge Black 35ppi Ceramic Noodles Sponge Blue 15ppi Media Basket 1 Media Basket 2 Media Basket 3 Ceramic Noodles ...

Страница 5: ...der Refer to previous page back into the canister body Ensure the filter inlet pipe has the black sealing O ring at the top of it and that the baskets sit flat on top of each other Fig 5 8 Ensure the filter grid is then placed back on top of the last filter basket This is very impor tant Fig 6 Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 1 Remove the 2 boxed accessory packs and the filter unit from the box 2 Ope...

Страница 6: ... top filter basket Fig 6 10 Line the filter inlet pipe up with the feeder pipe on the base of the head unit 11 Press down gently the bottom of the head unit should be flush with the canister body Be careful not to jam the power cord in between the canister and the head unit Do not force it together If it feels tight do not apply any pressure to close it simply remove the head unit and filter baske...

Страница 7: ... and cause it to leak Over tightening the tap will have the same effect NO TOOLS ARE REQUIRED HAND TIGHT IS ENOUGH 6 Place the canister in the desired position and feed the hose through the cabinet or stand Fig 4 7 Choose the outlet you wish to use and assemble it You will find you have 2 walking sticks the shorter one is used for the outlet 8 Outlet option 1 is the spray bar this can be set up to...

Страница 8: ...to the longer side of the walking stick k then attach the extension pipe m to the joiner Insert the lower end of the extension pipe into the undergravel attachment Fig 7 15 Place the undergravel plate into the bottom of the terrarium before gravel has been added Attach the completed intake assemply to the undergravel plate using the undergravel attachment 16 The strainer provided may be used as an...

Страница 9: ... running double check the fittings and seals for water tightness Fig 1 Fig 10 Fig 1 Installation Fig 11 Starting Your Filter On Off 1 The Primmer for your canister filter is located at the top of the head unit Fig 2 2 Press the primmer down either with your thumb or your palm Fig 3 3 Depress all the way then release Fig 4 Continue to pump the primer until the water flows down the inlet tube and be...

Страница 10: ... 4 Now wait until the siphon continues to fill the canister and eventually overfill into the bucket via the outlet pipe 5 The filter is primed when the intake pipe and filter is completely filled with water 6 Now place your thumb over the open end of the tubing or turn the taps to the off position 7 Reattach hose to the outlet pipe and affix the outlet pipe to your terrarium 8 Turn the taps back t...

Страница 11: ...askets and remove them from the canister body Fig 3 8 Remove the filter sponges and the white wool from the media baskets and dunk the baskets with the ceramic noodles Or any other type of biological media which may be in them several times into the bucket This will clear some of the dirt that can build up and clog the media and prevent the good bacteria which aid in breaking down pollutants in yo...

Страница 12: ...er through the hole in the middle of the impeller Clean any debris which may have built up on the shaft off along with any slime build up on the impeller Fig 8 18 Put the impeller back together and ensure that it rotates freely on the shaft Then reassemble the head unit ensure there is no water on the power cord plug the head unit in and turn on Make certain the impeller is spinning Turn it off Re...

Страница 13: ...through pipe THE FILTER WILL NOT PRIME 1 Check tubing for kinks 2 Make sure both taps are in the on position vertical 3 The terrarium needs to be filled 4 Make sure the intake tube and or intake strainer is not blocked 5 Ensure the hoses are connected to the unit correctly IN to IN and OUT to OUT 6 Ensure the canister has no water in it THE FILTER WILL NOT START 1 As the previous tips 2 Check the ...

Страница 14: ... Maximum Flow Rate 1250L hr Max Head Height 2M Filter Volume 12 Litres Power Requirements 220 240V Power Consumption 32W Suitable Reptiles Amphibians Made in China Designed in Australia by Reptile One Distributed in Australia by Kong s Aust Pty Limited 48 Williamson Rd Ingleburn 2565 NSW Australia Distributed in New Zealand by Kong s NZ Limited 52 Glenlyon Avenue Greerton Tauranga New Zealand Dist...

Страница 15: ...ation provided to us please refer to our Privacy Statement on the Reptile One websites or write to our Privacy Officer in your country of purchase 2 5 Where Reptile One determines goods are being used in a manner contrary to the instructions specifications or this Guarantee Reptile One reserves the right to terminate Extended Guarantee for such goods and will provide written notice to the purchase...

Страница 16: ... efficient and superior terrarium and vivarium products The Reptile One range includes a wide range of terrariums vivariums filters water heaters reflectors heating equipment lighting along with foods cleaning and maintenance accessories and decorations Keep an eye out for these Reptile One products at your local retailer www reptileone com au Instruction Version 08 04 2008 ...

Отзывы: