Aqua Lung Scout Swimmer Vest Скачать руководство пользователя страница 1

GENERAL WARNINGS

•  Before using the Scout Swimmer Vest you must read the instruction sheet completely.

•  Before using, inspect the entire Vest for leakage or other damage. If any part of this vest 

      does not function properly, or it is damaged, remove this Scout Swimmer Vest from service 

      until repaired.

•  Do not inhale from the Scout Swimmer Vest oral inflator. The vest may contain contaminants 

      from a previous CO2 firing or other sources.

•  The Scout Swimmer Vest is not approved for use in SCUBA diving.

Donning and Adjustment Procedures

1.  Place the Scout Swimmer Vest over your head. Next, route both straps underneath your 

      arms and through the D-rings, then tighten the straps (See Figure 1.)

2.  Fully inflate the Scout Swimmer Vest by loosening the knurl nut on the oral inflation tube 

      and depress the oral inflator valve. (See Figure 2.) Exhale into the valve until the vest is full. 

      If the fit is too tight, adjust the straps to comfort.

FIGURE 1

FIGURE 2

Pre-OP Check Out

Prior to each use, the vest should be given a thorough visual inspection and function test. 

1.  Fully inflate the vest and set aside for 30 minutes; loss of firmness indicates  leakage, 

        which must be corrected before use.

2.  Ensure that all stitched together components are not separating.

3.   Check that the oral inflation tube and valve properly function by depressing the valve and 

       blowing into the tube. Ensure the knurl nut on the oral inflation tube freely turns.

4.  Remove the CO2 cartridges and inspect both actuators. Ensure the actuator operates 

       correctly by pulling on the toggle and checking that the pin travels up and down. Return the 

       actuating arm to the UP position prior to rethreading the CO2 cartridge into the actuator.

5.  Perform a function check on the over-pressure relief valve by fully inflating the vest and 

       then squeezing the vest to ensure the valve opens, allowing air to escape. Next pull the 

       toggle to ensure the valve is correctly working by allowing air to escape. (See Figure 3.)

 

NOTE: Over-Pressure Relief Valve will actuate when the pressure inside the vest exceeds 

       2 PSI greater than external pressure.