Initial Start-up:  

Read all of the instructions before energizing unit. 

 

Caution:

 When the ambient air temperature is 60°F and below a compressor crankcase heater must be installed. 

It’s important to allow the oil in the compressor to warm-up at least 8 hours before starting up the unit. If the 

ambient air temperature is below 60˚F, apply power to the unit and set controller so the compressor does not 

energize or by-pass the heat exchanger water supply so the flow switch will not activate the unit. 

 

 

1.

 

Turn on water pump and set the correct water flow rate. 

2.

 

Apply power to the unit. 

3.

 

Adjust temperature controller set point to desired water temperature.  

(See “Heat pump Control Set-up”)  

 

Cooling: 

When the temperature control calls for cooling, the heat pump will turn on and pull the water 

temperature down to the desired set point and then shut off. When the water temperature 

rises above the differential setting, the heat pump will repeat the cycle and cool down to 

temperature set point.  

 

Heating: 

When the temperature control calls for heating, the heat pump will turn on and heat the water 

temperature up to the desired set point and then shut off. When the water temperature goes 

down below the differential setting, the heat pump will repeat the cycle and heat up to the 

temperature set point. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание DSHP Series

Страница 1: ...s heat pump It has been designed and built to provide years of reliable trouble free service It provides a precise water temperature control up to 1 0 F 0 7 C accuracy and features a continuous LCD di...

Страница 2: ...PECTION Protect yourself File your claim immediately with the transportation company Remember Aqua logic Inc is not responsible for any damage after the carrier accepts a shipment Claim for FULL VALUE...

Страница 3: ...exist where heat pump is to be located care must be taken to prevent water from getting on electrical components 4 On some heat pump models allow only qualified licensed personnel to supply electric p...

Страница 4: ...tings on the front of the heat pump Be careful not to over tighten the plastic fittings 3 Install flow switch if supplied either on the water inlet or outlet side with at least 12 inches of straight p...

Страница 5: ...mp and set the correct water flow rate 2 Apply power to the unit 3 Adjust temperature controller set point to desired water temperature See Heat pump Control Set up Cooling When the temperature contro...

Страница 6: ...s either up key to increase or the down key to select the correct Stage 1 mode Stage 1 MUST be in the H1 mode for correct operation 5 Press the SET key again to access the chill mode set point tempera...

Страница 7: ...the heat pump If there is no air or low air flow through the condenser the pressure will build up and cause the switch to trip off When there a refrigerant leak the switch will protect the heat pump f...

Страница 8: ...d or bleach into the water DO pour water into acid or bleach solution DO NOT perform acid and bleach flushing at the same time The gas generated by the mixture is poisonous and can result in serious i...

Страница 9: ...OK Wiring Replace flow switch Pressure Cutout Switch 1 Check condenser entering water flow and water temperature 2 Check for low refrigerant pressure Check Refrigerant level 3 Liquid gauge high pressu...

Страница 10: ...intenance by user or their agent Damage caused due to misapplication of product Damage caused by corrosion abuse accident alteration or improper use Damage caused by flood fire earthquake tornado or o...

Отзывы: